343 682

Cited 19 times in

Comparison of OCT and HRT Findings Among Normal, Normal Tension Glaucoma, and High Tension Glaucoma

Authors
 In Ha Shin  ;  Sung Yong Kang  ;  Samin Hong  ;  Seung Kab Kim  ;  Gong Je Seong  ;  Kyoung Tak Ma  ;  Chan Yun Kim 
Citation
 Korean Journal of Ophthalmology, Vol.22(4) : 236-241, 2008 
Journal Title
Korean Journal of Ophthalmology
ISSN
 1011-8942 
Issue Date
2008
MeSH
Adult ; Aged ; Axons/pathology* ; Diagnostic Techniques, Ophthalmological* ; Female ; Glaucoma, Open-Angle/diagnosis* ; Humans ; Male ; Middle Aged ; Ocular Hypertension/diagnosis ; Optic Disk/pathology* ; Optic Nerve Diseases/diagnosis* ; Retinal Ganglion Cells/pathology* ; Retrospective Studies ; Tomography, Optical Coherence* ; Visual Field Tests ; Visual Fields
Keywords
High tension glaucoma ; Normal tension glaucoma ; Retinal nerve fiber layer
Abstract
Purpose: To evaluate the relationship between optic disc and retinal nerve fiber layer (RNFL) measurements obtained with the optical coherence tomography (OCT) and the Heidelberg retina topography (HRT) in normal, normal tension glaucoma (NTG), and high tension glaucoma (HTG). Methods: Normal, NTG and HTG subjects who met inclusion and exclusion criteria were evaluated retrospectively. One hundred seventy eyes of 170 patients (30 normal, 40 NTG, and 100 HTG) were enrolled. Complete ophthalmologic examination, HRT, OCT, and automated perimetry were evaluated. Results: Disc area, cup area and cup/disc area ratio measured with HRT were significantly different between NTG and HTG (all p<0.05). Mean RNFL thickness measured by OCT with ascanning diameter of 3.4 mm was larger in NTG than HTG (84.97±24.20 ㎛ vs. 73.53±27.17 ㎛, p=0.037). Four quadrant RNFL thickness measurements were not significantly different between NTG and HTG (all p>0.05). Mean deviation and corrected pattern standard deviation measured by automated perimetry was significantly correlated with mean and inferior RNFL thickness in both NTG and HTG (Pearson`s r, p<0.05). Mean RNFL thickness/disc area ratio was significantly larger in HTG than NTG (35.21±18.92 vs. 31.30±10.91, p=0.004). Conclusions: These findings suggest that optic disc and RNFL damage pattern in NTG may be different from those of HTG
Files in This Item:
T200805209.pdf Download
DOI
10.3341/kjo.2008.22.4.236
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers
Yonsei Authors
Kang, Sung Yong(강성용)
Kim, Seung Kab(김승갑)
Kim, Chan Yun(김찬윤) ORCID logo https://orcid.org/0000-0002-8373-9999
Ma, Kyung Tak(마경탁)
Seong, Gong Je(성공제) ORCID logo https://orcid.org/0000-0002-5456-4296
Hong, Sa Min(홍사민)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/108347
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links