681 823

Cited 0 times in

교육이 유방 초음파의 전문성에 미치는 영향

DC Field Value Language
dc.contributor.author김은경-
dc.contributor.author이미정-
dc.contributor.author최은희-
dc.contributor.author곽진영-
dc.contributor.author김민정-
dc.date.accessioned2015-05-19T17:21:26Z-
dc.date.available2015-05-19T17:21:26Z-
dc.date.issued2008-
dc.identifier.issn1015-7085-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/107993-
dc.description.abstractPurpose: This study was designed to evaluate the effectiveness of the training experience to develop expertise for breast ultrasound. The same group of radiology residents was evaluated before and after training on the use of the Breast Imaging Reporting and Data System (BI-RADS) to develop breast imaging expertise. Materials and Method : An evaluation set of breast ultrasonography images of pathologically confirmed lesions that consisted of 100 masses (54 benign and 46 malignant masses) without clinical information was developed. Two experienced breast radiologists independently reviewed cases to reach a consensus. Six radiology residents (four second-year residents and two third-year residents) trained one month to interpret breast ultrasound examinations, and to read and to review teaching files with expertise. The residents evaluated the examination set according to BI-RADS for shape, orientation, margin, lesion-boundary, echo pattern, posterior echo features, surrounding tissue, calcification and final assessment before and after the training. Training performance was measured by means of agreement (k) and diagnostic performance. Results: After training, the second-year residents showed statistically significant increased agreement as compared to the experts for 15 of the total 36 BI-RADS descriptors. The third-year residents showed increased agreement for three of the 18 descriptors. The mean sensitivity for the residents was 94.2% (range, 89.1-100%) before training and the mean sensitivity increased to 97.8% (range, 95.7-100%) after training. The mean specificity was 50.6% (range, 40.7-59.3%) before training and the mean specificity decreased to 42.0% (range, 31.5-51.9%) after training. Conclusion: In this study, the use of breast ultrasonography training improved the ability of residents to determine lesion description, final assessment and coherence-
dc.description.statementOfResponsibilityopen-
dc.format.extent179~187-
dc.relation.isPartOfJournal of the Korean Society of Medical Ultrasound (대한초음파의학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title교육이 유방 초음파의 전문성에 미치는 영향-
dc.title.alternativeThe Influence of Training on Breast Ultrasound Expertise-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiology (영상의학)-
dc.contributor.googleauthor백송이-
dc.contributor.googleauthor김민정-
dc.contributor.googleauthor김은경-
dc.contributor.googleauthor최은희-
dc.contributor.googleauthor구혜령-
dc.contributor.googleauthor김지연-
dc.contributor.googleauthor김한솔-
dc.contributor.googleauthor박성호-
dc.contributor.googleauthor윤정현-
dc.contributor.googleauthor이미정-
dc.contributor.googleauthor이승우-
dc.contributor.googleauthor곽진영-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00801-
dc.contributor.localIdA04163-
dc.contributor.localIdA00182-
dc.contributor.localIdA00473-
dc.contributor.localIdA02774-
dc.relation.journalcodeJ01882-
dc.identifier.pmidBreast US ; BI-RADS ; training-
dc.subject.keywordBreast US-
dc.subject.keywordBI-RADS-
dc.subject.keywordtraining-
dc.contributor.alternativeNameKim, Eun Kyung-
dc.contributor.alternativeNameLee, Mi Jung-
dc.contributor.alternativeNameChoi, Eun Hee-
dc.contributor.alternativeNameKwak, Jin Young-
dc.contributor.alternativeNameKim, Min Jung-
dc.contributor.affiliatedAuthorKim, Eun-Kyung-
dc.contributor.affiliatedAuthorChoi, Eun Hee-
dc.contributor.affiliatedAuthorKwak, Jin Young-
dc.contributor.affiliatedAuthorKim, Min Jung-
dc.contributor.affiliatedAuthorLee, Mi Jung-
dc.rights.accessRightsfree-
dc.citation.volume27-
dc.citation.number4-
dc.citation.startPage179-
dc.citation.endPage187-
dc.identifier.bibliographicCitationJournal of the Korean Society of Medical Ultrasound (대한초음파의학회지), Vol.27(4) : 179-187, 2008-
dc.identifier.rimsid50048-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Biomedical Systems Informatics (의생명시스템정보학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.