dc.description.abstractOBJECTIVE: To validate the use of contrast-enhanced (CE) fat-suppressed three-dimensional (3D) fast gradient-recalled acquisition in the steady state with radiofrequency spoiling (FSPGR) magnetic resonance imaging (MRI) for the diagnosis of anterolateral soft tissue impingement of the ankle, as compared to the use of routine ankle MRI. MATERIALS AND METHODS: Contrast-enhanced fat-suppressed 3D-FSPGR MRI and routine MRI scans were retrospectively reviewed for 45 patients with arthroscopically proven anterolateral impingement. In addition, scans were reviewed in 45 control subjects with diagnoses other than impingement. Two radiologists independently reviewed the two sets of images in random order. Using areas (Az) under the receiver operating characteristic curve (ROC), we compared the depiction of anterolateral soft tissue impingement in the two sets of images. RESULTS: The overall accuracy for lesion characterization was significantly higher (p < 0.05) using the CE fat-suppressed 3D-FSPGR MR images (Az = 0.892 and 0.881 for reader 1 and 2, respectively) than using the routine MR images (Az = 0.763 and 0.745). The use of CE fat-suppressed 3D-FSPGR MRI enhanced impingement depiction in most cases. However, in cases with a thickened non-enhancing scar or joint effusion, the routine images better depicted a soft tissue mass that intruded into anterolateral gutter than the CE images. CONCLUSION: The use of CE fat-suppressed 3D-FSPGR MRI of the ankle allows a more accurate assessment of anterolateral soft tissue impingement of the ankle, as compared to the use of routine MRI-
dc.description.statementOfResponsibilityopen-
dc.format.extent409~415-
dc.relation.isPartOfKOREAN JOURNAL OF RADIOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAdolescent-
dc.subject.MESHAdult-
dc.subject.MESHAged-
dc.subject.MESHAnkle Joint/pathology*-
dc.subject.MESHContrast Media-
dc.subject.MESHFemale-
dc.subject.MESHGadolinium DTPA-
dc.subject.MESHHumans-
dc.subject.MESHImage Interpretation, Computer-Assisted-
dc.subject.MESHImaging, Three-Dimensional-
dc.subject.MESHJoint Diseases/diagnosis*-
dc.subject.MESHMagnetic Resonance Imaging/methods*-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHROC Curve-
dc.subject.MESHRetrospective Studies-
dc.subject.MESHSensitivity and Specificity-
dc.subject.MESHStatistics, Nonparametric-
dc.titleAnkle MRI for anterolateral soft tissue impingement: increased accuracy with the use of contrast-enhanced fat-suppressed 3D-FSPGR MRI-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Orthopedic Surgery (정형외과학)-
dc.contributor.googleauthorHye Jung Choo-
dc.contributor.googleauthorJin-Suck Suh-
dc.contributor.googleauthorSung-Jun Kim-
dc.contributor.googleauthorYong-Min Huh-
dc.contributor.googleauthorMyung In Kim-
dc.contributor.googleauthorJin-Woo Lee-
dc.identifier.doi10.3348/kjr.2008.9.5.409-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00585-
dc.contributor.localIdA01916-
dc.contributor.localIdA03230-
dc.contributor.localIdA04359-
dc.relation.journalcodeJ02884-
dc.identifier.eissn2005-8330-
dc.identifier.pmid18838849-
dc.subject.keywordAnkle-
dc.subject.keywordabnormalities-
dc.subject.keywordAnkle-
dc.subject.keywordinjuries-
dc.subject.keywordAnkle-
dc.subject.keywordMR-
dc.contributor.alternativeNameKim, Sung Jun-
dc.contributor.alternativeNameSuh, Jin Suck-
dc.contributor.alternativeNameLee, Jin Woo-
dc.contributor.alternativeNameHuh, Yong Min-
dc.contributor.affiliatedAuthorKim, Sung Jun-
dc.contributor.affiliatedAuthorSuh, Jin Suck-
dc.contributor.affiliatedAuthorLee, Jin Woo-
dc.contributor.affiliatedAuthorHuh, Yong Min-
dc.rights.accessRightsfree-
dc.citation.volume9-
dc.citation.number5-
dc.citation.startPage409-
dc.citation.endPage415-
dc.identifier.bibliographicCitationKOREAN JOURNAL OF RADIOLOGY, Vol.9(5) : 409-415, 2008-
dc.identifier.rimsid34663-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Orthopedic Surgery (정형외과학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.