1 473

Cited 98 times in

Management of dislocated intraocular lenses

Authors
 Sung Soo Kim  ;  William E. Smiddy  ;  William Feuer  ;  Wei Shi 
Citation
 OPHTHALMOLOGY, Vol.115(10) : 1699-1704, 2008 
Journal Title
OPHTHALMOLOGY
ISSN
 0161-6420 
Issue Date
2008
Abstract
PURPOSE: The purpose of this study was to characterize the contemporary clinical presentation and treatment results of patients with dislocated intraocular lenses (IOLs).

DESIGN: Retrospective, noncomparative, single-surgeon interventional case series.

PARTICIPANTS: Two hundred eighty-four eyes of 277 patients operated for dislocated IOLs; 184 eyes with >3 months follow-up information were analyzed for visual outcomes.

METHODS: Review of preoperative, intraoperative, and postoperative clinical features from patient charts.

MAIN OUTCOME MEASURES: Best-corrected visual acuity, reoperations, and complications such as retinal detachment and postoperative refraction.

RESULTS: The study included eyes with polymethyl methacrylate IOLs (n = 113), silicone plate IOLs (n = 51), 3-piece silicone IOLs (n = 38), acrylic IOLs (n = 60), and others (n = 12). There were 51 (18%) with "in-the-bag" IOL dislocations; their proportion increased during the study period and were associated with pseudoexfoliation (P = 0.01), ocular trauma (P = 0.013), and time after implantation of IOL (P = 0.006). Recurrent dislocation (17 eyes; 6%) and decentration (11 eyes; 4%) of IOLs occurred, and resulted in further surgery in 18 (6%) eyes, but were not related to the types of IOL or surgical technique. The most common complication was cystoid macular edema (29 eyes; 10%); retinal detachment occurred after management of dislocated IOL in 11 (4%) eyes. Visual results and median postoperative refractive changes for the 184 eyes with follow-up >3 months were similar regardless of surgical techniques.

CONCLUSIONS:

Currently, IOL dislocation more commonly involves foldable IOLs and in-the-bag dislocation. Existing techniques of IOL repositioning with or without scleral suture fixation or IOL exchange are effective for contemporary dislocated IOLs. Preexisting conditions and postoperative complications may limit the visual outcomes
Full Text
http://www.sciencedirect.com/science/article/pii/S0161642008003771
DOI
10.1016/j.ophtha.2008.04.016
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Sung Soo(김성수) ORCID logo https://orcid.org/0000-0002-0574-7993
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/107654
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links