Cited 46 times in
Saline flush effect for enhancement of aorta and coronary arteries at multidetector CT coronary angiography
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 최병욱 | - |
dc.contributor.author | 김상진 | - |
dc.contributor.author | 김영진 | - |
dc.contributor.author | 김태훈 | - |
dc.contributor.author | 유영훈 | - |
dc.date.accessioned | 2015-05-19T16:50:34Z | - |
dc.date.available | 2015-05-19T16:50:34Z | - |
dc.date.issued | 2008 | - |
dc.identifier.issn | 0033-8419 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/107044 | - |
dc.description.abstract | PURPOSE: To prospectively investigate the effect of the injection rate of a saline solution as a bolus chaser for the enhancement of the aorta and coronary arteries at multidetector computed tomographic (CT) coronary angiography. MATERIALS AND METHODS: Institutional review board approved this study, and all patients gave informed consent. One hundred consecutive patients (59 men, 41 women; mean age, 58 years +/- 11 [standard deviation]) underwent 64-section CT coronary angiography for coronary artery disease. They were divided into five groups (each group, n = 20) according to the injection rate of saline solution (3, 4, 5, 6, and 7 mL/sec). Iodinated contrast medium (60 mL) was injected intravenously at a rate of 4 mL/sec, followed by 60 mL saline solution administered intravenously at a rate of 3-7 mL/sec, depending on the groups. Attenuation values of the aortic root, right coronary artery, left anterior descending artery, and left circumflex artery were measured. Analysis of variance with the Scheffé method was used to evaluate statistical significance of the differences in attenuation according to the injection rate of saline solution. RESULTS: The degree of contrast enhancement was affected by the injection rate of saline solution, and the attenuation values were higher as the injection rate increased up to 4-5 mL/sec (P < .05). The values plateaued at rates over 5 mL/sec in the aorta and over 4 mL/sec in the coronary arteries. CONCLUSION: An injection rate of 4-5 mL/sec as a saline solution chaser is optimal for achieving maximum attenuation values of the aorta or coronary arteries by using 64-section CT with 60 mL contrast material | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 110~115 | - |
dc.relation.isPartOf | RADIOLOGY | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Adult | - |
dc.subject.MESH | Aged | - |
dc.subject.MESH | Aged, 80 and over | - |
dc.subject.MESH | Aortography/methods* | - |
dc.subject.MESH | Contrast Media/administration & dosage* | - |
dc.subject.MESH | Coronary Angiography/methods* | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Injections, Intravenous | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Middle Aged | - |
dc.subject.MESH | Prospective Studies | - |
dc.subject.MESH | Sodium Chloride/administration & dosage* | - |
dc.subject.MESH | Tomography, X-Ray Computed* | - |
dc.title | Saline flush effect for enhancement of aorta and coronary arteries at multidetector CT coronary angiography | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Nuclear Medicine (핵의학) | - |
dc.contributor.googleauthor | Dae Jung Kim | - |
dc.contributor.googleauthor | Tae Hoon Kim | - |
dc.contributor.googleauthor | Sang Jin Kim | - |
dc.contributor.googleauthor | Dong Phil Kim | - |
dc.contributor.googleauthor | Chi Suk Oh | - |
dc.contributor.googleauthor | Young Hoon Ryu | - |
dc.contributor.googleauthor | Young Jin Kim | - |
dc.contributor.googleauthor | Byoung Wook Choi | - |
dc.identifier.doi | 10.1148/radiol.2453061953 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A04059 | - |
dc.contributor.localId | A00528 | - |
dc.contributor.localId | A02485 | - |
dc.contributor.localId | A00727 | - |
dc.contributor.localId | A01086 | - |
dc.relation.journalcode | J02596 | - |
dc.identifier.eissn | 1527-1315 | - |
dc.identifier.pmid | 18096532 | - |
dc.identifier.url | http://pubs.rsna.org/doi/abs/10.1148/radiol.2453061953 | - |
dc.subject.keyword | Adult | - |
dc.subject.keyword | Aged | - |
dc.subject.keyword | Aged, 80 and over | - |
dc.subject.keyword | Aortography/methods* | - |
dc.subject.keyword | Contrast Media/administration & dosage* | - |
dc.subject.keyword | Coronary Angiography/methods* | - |
dc.subject.keyword | Female | - |
dc.subject.keyword | Humans | - |
dc.subject.keyword | Injections, Intravenous | - |
dc.subject.keyword | Male | - |
dc.subject.keyword | Middle Aged | - |
dc.subject.keyword | Prospective Studies | - |
dc.subject.keyword | Sodium Chloride/administration & dosage* | - |
dc.subject.keyword | Tomography, X-Ray Computed* | - |
dc.contributor.alternativeName | Choi, Byoung Wook | - |
dc.contributor.alternativeName | Kim, Sang Jin | - |
dc.contributor.alternativeName | Kim, Young Jin | - |
dc.contributor.alternativeName | Kim, Tae Hoon | - |
dc.contributor.alternativeName | Ryu, Young Hoon | - |
dc.contributor.affiliatedAuthor | Choi, Byoung Wook | - |
dc.contributor.affiliatedAuthor | Kim, Sang Jin | - |
dc.contributor.affiliatedAuthor | Ryu, Young Hoon | - |
dc.contributor.affiliatedAuthor | Kim, Young Jin | - |
dc.contributor.affiliatedAuthor | Kim, Tae Hoon | - |
dc.rights.accessRights | not free | - |
dc.citation.volume | 246 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 110 | - |
dc.citation.endPage | 115 | - |
dc.identifier.bibliographicCitation | RADIOLOGY, Vol.246(1) : 110-115, 2008 | - |
dc.identifier.rimsid | 49487 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.