1 680

Cited 8 times in

Posterior capsulectomy using a 25-gauge microincision vitrectomy system for preventing secondary opacification after congenital cataract surgery: outcome up to 4 years

Authors
 Samin Hong  ;  Gong Je Seong  ;  Sung Soo Kim 
Citation
 CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, Vol.44(4) : 441-443, 2009 
Journal Title
CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE
ISSN
 0008-4182 
Issue Date
2009
MeSH
Cataract/congenital ; Cataract/prevention & control* ; Child ; Child, Preschool ; Female ; Follow-Up Studies ; Humans ; Lens Capsule, Crystalline/surgery* ; Lens Implantation, Intraocular ; Male ; Microsurgery/methods* ; Phacoemulsification/methods* ; Postoperative Complications/prevention & control* ; Retrospective Studies ; Treatment Outcome ; Visual Acuity/physiology ; Vitrectomy/methods*
Keywords
congenital cataract ; posterior capsulectomy ; 25-gauge microincision vitrectomy
Abstract
OBJECTIVE: To assess long-term outcomes of posterior capsulectomy using a 25-gauge microincision vitrectomy system (25-GV) for preventing secondary visual axis opacification after congenital cataract surgery.

STUDY DESIGN: Retrospective noncomparative case series.

PARTICIPANTS: Nine eyes of 5 children who underwent posterior capsulectomy carried out with the use of a 25-GV during congenital cataract surgery.

METHODS: After removal of congenital cataract with phacoemulsification and intraocular lens implantation, the posterior capsulectomy was performed using a 25-GV. Postoperative visual outcomes were analyzed.

RESULTS: The mean follow-up period was 43.11 (SD 5.53) months. Eight eyes maintained a clear visual axis, but 1 eye required Nd:YAG capsulotomy to enlarge the opening of the capsulectomy at 7 months postoperatively. Postoperative visual acuity was maintained up to 4 years without any other complications.

CONCLUSIONS: Posterior capsulectomy using a 25-GV offers an option for preventing secondary visual axis opacification after congenital cataract surgery.
Full Text
http://www.sciencedirect.com/science/article/pii/S0008418209801956
DOI
10.3129/i09-118
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Sung Soo(김성수) ORCID logo https://orcid.org/0000-0002-0574-7993
Seong, Gong Je(성공제) ORCID logo https://orcid.org/0000-0002-5456-4296
Hong, Sa Min(홍사민)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/105027
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links