Cited 0 times in
Sonographic elastography combined with conventional sonography: how much is it helpful for diagnostic performance?
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 곽진영 | - |
dc.contributor.author | 김민정 | - |
dc.contributor.author | 김수진 | - |
dc.contributor.author | 김은경 | - |
dc.contributor.author | 문희정 | - |
dc.contributor.author | 손유미 | - |
dc.date.accessioned | 2015-04-24T16:34:29Z | - |
dc.date.available | 2015-04-24T16:34:29Z | - |
dc.date.issued | 2009 | - |
dc.identifier.issn | 0278-4297 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/103769 | - |
dc.description.abstract | OBJECTIVE: The purpose of this study was to evaluate the diagnostic performance of conventional sonography combined with sonographic elastography for differentiation between benign and malignant breast lesions and to assess the diagnostic performance with two types of interpretation criteria for sonographic elastography. METHODS: For this study, we included 281 lesions from 267 patients that were diagnosed as benign or malignant by sonographically guided biopsy and prospectively analyzed by conventional sonography and sonographic elastography from October to December 2007. The histopathologic results from sonographically guided biopsy were used as a reference standard. The final assessments were made prospectively on the basis of conventional sonography alone and then by sonographic elastography combined with conventional sonography. The diagnostic performance using area under the receiver operating characteristic (ROC) curve analysis (A(z)) was compared on the basis of conventional sonography alone and on elastography combined with conventional sonography. We also calculated the area ratio of lesions detected by elastography and the elasticity score reported by Itoh et al (Radiology 2006; 239:341-350). RESULTS: The areas under the ROC curve for conventional sonography and the combination of conventional sonography and sonographic elastography were 0.927 and 0.876, respectively. The area ratio of the lesion had better diagnostic performance (A(z), 0.757) than the elasticity score (A(z), 0.54; P < .05). CONCLUSIONS: The diagnostic performance of radiologists with respect to the characterization of breast masses as benign or malignant was not significantly improved with sonographic elastography. The area ratio of the lesion had a better diagnostic value in elastography than the elasticity score. | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 413~420 | - |
dc.relation.isPartOf | JOURNAL OF ULTRASOUND IN MEDICINE | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Breast Neoplasms/diagnostic imaging* | - |
dc.subject.MESH | Elasticity Imaging Techniques/methods* | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Image Enhancement/methods | - |
dc.subject.MESH | Image Interpretation, Computer-Assisted/methods* | - |
dc.subject.MESH | Reproducibility of Results | - |
dc.subject.MESH | Sensitivity and Specificity | - |
dc.subject.MESH | Ultrasonography, Mammary/methods* | - |
dc.title | Sonographic elastography combined with conventional sonography: how much is it helpful for diagnostic performance? | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Radiology (영상의학) | - |
dc.contributor.googleauthor | Yu-Mee Sohn | - |
dc.contributor.googleauthor | Min Jung Kim | - |
dc.contributor.googleauthor | Eun-Kyung Kim | - |
dc.contributor.googleauthor | Jin Young Kwak | - |
dc.contributor.googleauthor | Hee Jung Moon | - |
dc.contributor.googleauthor | Soo Jin Kim | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A00635 | - |
dc.contributor.localId | A00473 | - |
dc.contributor.localId | A00182 | - |
dc.contributor.localId | A00801 | - |
dc.contributor.localId | A01397 | - |
dc.contributor.localId | A01986 | - |
dc.relation.journalcode | J01920 | - |
dc.identifier.eissn | 1550-9613 | - |
dc.identifier.pmid | 19321669 | - |
dc.contributor.alternativeName | Kwak, Jin Young | - |
dc.contributor.alternativeName | Kim, Min Jung | - |
dc.contributor.alternativeName | Kim, Soo Jin | - |
dc.contributor.alternativeName | Kim, Eun Kyung | - |
dc.contributor.alternativeName | Moon, Heui Jeong | - |
dc.contributor.alternativeName | Sohn, Yu Mee | - |
dc.contributor.affiliatedAuthor | Kim, Soo Jin | - |
dc.contributor.affiliatedAuthor | Kim, Min Jung | - |
dc.contributor.affiliatedAuthor | Kwak, Jin Young | - |
dc.contributor.affiliatedAuthor | Kim, Eun-Kyung | - |
dc.contributor.affiliatedAuthor | Moon, Heui Jeong | - |
dc.contributor.affiliatedAuthor | Sohn, Yu Mee | - |
dc.citation.volume | 28 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 413 | - |
dc.citation.endPage | 420 | - |
dc.identifier.bibliographicCitation | JOURNAL OF ULTRASOUND IN MEDICINE, Vol.28(4) : 413-420, 2009 | - |
dc.identifier.rimsid | 36682 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.