405 453

Cited 0 times in

High Resolution Time Resolved Contrast Enhanced MR Angiography Using k-t FOCUSS

DC Field Value Language
dc.contributor.author김응엽-
dc.date.accessioned2015-04-23T17:48:06Z-
dc.date.available2015-04-23T17:48:06Z-
dc.date.issued2010-
dc.identifier.issn1226-9751-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/103159-
dc.description.abstractPURPOSE: Recently, the Recon Challenge at the 2009 ISMRM workshop on Data Sampling and Image Reconstruction at Sedona, Arizona was held to evaluate feasibility of highly accelerated acquisition of time resolved contrast enhanced MR angiography. This paper provides the step-by-step description of the winning results of k-t FOCUSS in this competition. MATERIALS AND METHODS: In previous works, we proved that k-t FOCUSS algorithm successfully solves the compressed sensing problem even for less sparse cardiac cine applications. Therefore, using k-t FOCUSS, very accurate time resolved contrast enhanced MR angiography can be reconstructed. Accelerated radial trajectory data were synthetized from X-ray cerebral angiography images and provided by the organizing committee, and radiologists double blindly evaluated each reconstruction result with respect to the ground-truth data. RESULTS: The reconstructed results at various acceleration factors demonstrate that each components of compressed sensing, such as sparsifying transform and incoherent sampling patterns, etc can have profound effects on the final reconstruction results. CONCLUSION: From reconstructed results, we see that the compressed sensing dynamic MR imaging algorithm, k-t FOCUSS enables high resolution time resolved contrast enhanced MR angiography-
dc.description.statementOfResponsibilityopen-
dc.format.extent10~20-
dc.relation.isPartOfJournal of the Korean Society of Magnetic Resonance in Medicine (대한자기공명의과학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titleHigh Resolution Time Resolved Contrast Enhanced MR Angiography Using k-t FOCUSS-
dc.title.alternativek-t FOCUSS 알고리듬을 이용한 고분해능 4-D MR 혈관 조영 영상 기법-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiology (영상의학)-
dc.contributor.googleauthorHong Jung-
dc.contributor.googleauthorEung Yeop Kim-
dc.contributor.googleauthorJong Chul Ye-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00832-
dc.relation.journalcodeJ01880-
dc.subject.keywordTime resolved contrast enhanced MR angiography-
dc.subject.keywordCompressed sensing-
dc.subject.keywordk-t FOCUSS-
dc.subject.keywordKarhunen-Loeve Transform-
dc.subject.keywordPrincipal component analysis-
dc.contributor.alternativeNameKim, Eung Yeop-
dc.contributor.affiliatedAuthorKim, Eung Yeop-
dc.citation.volume14-
dc.citation.number1-
dc.citation.startPage10-
dc.citation.endPage20-
dc.identifier.bibliographicCitationJournal of the Korean Society of Magnetic Resonance in Medicine (대한자기공명의과학회지), Vol.14(1) : 10-20, 2010-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.