378 785

Cited 0 times in

CT를 이용한 비석회화 죽상경화반의 측정에 있어서 내강의 조영 정도가 미치는 영향에 대한 실험적 연구: T1 강조 자기공명영상과의 비교

DC Field Value Language
dc.contributor.author최규옥-
dc.contributor.author최병욱-
dc.contributor.author허진-
dc.contributor.author김영진-
dc.contributor.author김태훈-
dc.contributor.author이혜정-
dc.date.accessioned2015-04-23T17:36:59Z-
dc.date.available2015-04-23T17:36:59Z-
dc.date.issued2010-
dc.identifier.issn1738-2637-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/102803-
dc.description.abstractPURPOSE: We studied early and delayed contrast-enhanced CT to determine the effects of the degree of luminal enhancement on the measurement of plaque size compared to T1-weighted MRI. MATERIALS AND METHODS: T1-weighted MRI and a two-phase contrast-enhanced CT was performed in 5 New Zealand white rabbits with atherosclerosis. Early-phase images were acquired during an expected peak enhancement period of the lumen; delayed-phase images were acquired 240 sec after administration of the contrast media. Anteroposterior and lateral luminal diameters (APD, LD), luminal area (LA), total vessel area (TVA), and plaque area (PA) of the aorta were measured on MRI and CT, respectively and compared to each other. RESULTS: A total of 78 slices of the aorta were analyzed. PA, measured on T1-weighted MR images, was significantly greater than PA for both early-phase and delayed-phase CT (p < 0.001). The mean difference in PA was 12.13 +/- 5.52 mm2 (p < 0.001), 11.51 +/- 4.37 mm2 (p < 0.001), -0.62 +/- 3.87 mm2 (p = 0.159) for MRI vs. early-phase CT, MRI vs. delayed-phase CT, and early-phase CT vs. delayed-phase CT, respectively. CONCLUSION: Different luminal densities by contrast enhancement do not affect the CT measurement of plaque area for the detection of obstructive coronary artery disease-
dc.description.statementOfResponsibilityopen-
dc.format.extent329~337-
dc.languageKorean-
dc.publisher대한영상의학회-
dc.relation.isPartOfJournal of the Korean Society of Radiology-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titleCT를 이용한 비석회화 죽상경화반의 측정에 있어서 내강의 조영 정도가 미치는 영향에 대한 실험적 연구: T1 강조 자기공명영상과의 비교-
dc.title.alternativeThe Effect of the Degree of Luminal Contrast-Enhancement on CT Measurement of Plaque Size: A Comparison with T1-weighted Magnetic Resonance Imaging-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiology (영상의학)-
dc.contributor.googleauthorByoung Wook Choi-
dc.contributor.googleauthorJin Hur-
dc.contributor.googleauthorHye-Jeong Lee-
dc.contributor.googleauthorYoung Jin Kim-
dc.contributor.googleauthorTae Hoon Kim-
dc.contributor.googleauthorKyu Ok Choe-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA03320-
dc.contributor.localIdA00727-
dc.contributor.localIdA01086-
dc.contributor.localIdA04042-
dc.contributor.localIdA04059-
dc.contributor.localIdA04370-
dc.relation.journalcodeJ01843-
dc.identifier.eissn2288-2928-
dc.subject.keywordAtherosclerosis-
dc.subject.keywordTomography, X-Ray Computed-
dc.subject.keywordMagnetic Resonance Imaging-
dc.subject.keywordAorta, Coronary Diseases-
dc.subject.keywordRabbits-
dc.contributor.alternativeNameChoe, Kyu Ok-
dc.contributor.alternativeNameChoi, Byoung Wook-
dc.contributor.alternativeNameHur, Jin-
dc.contributor.alternativeNameKim, Young Jin-
dc.contributor.alternativeNameKim, Tae Hoon-
dc.contributor.alternativeNameLee, Hye Jeong-
dc.contributor.affiliatedAuthorLee, Hye Jeong-
dc.contributor.affiliatedAuthorKim, Young Jin-
dc.contributor.affiliatedAuthorKim, Tae Hoon-
dc.contributor.affiliatedAuthorChoe, Kyu Ok-
dc.contributor.affiliatedAuthorChoi, Byoung Wook-
dc.contributor.affiliatedAuthorHur, Jin-
dc.citation.volume63-
dc.citation.number4-
dc.citation.startPage329-
dc.citation.endPage337-
dc.identifier.bibliographicCitationJournal of the Korean Society of Radiology, Vol.63(4) : 329-337, 2010-
dc.identifier.rimsid34824-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.