377 630

Cited 22 times in

Evaluation of Left Atrial Volumes Using Multidetector Computed Tomography: Comparison with Echocardiography

DC Field Value Language
dc.contributor.author김상진-
dc.contributor.author김태훈-
dc.contributor.author이상민-
dc.contributor.author임세중-
dc.contributor.author홍유진-
dc.date.accessioned2015-04-23T16:54:48Z-
dc.date.available2015-04-23T16:54:48Z-
dc.date.issued2010-
dc.identifier.issn1229-6929-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/101466-
dc.description.abstractOBJECTIVE: To prospectively assess the relationship between the two different measurement methods for the evaluation of left atrial (LA) volume using cardiac multidetector computed tomography (MDCT) and to compare the results between cardiac MDCT and echocardiography. MATERIALS AND METHODS: Thirty-five patients (20 men, 15 women; mean age, 60 years) underwent cardiac MDCT angiography for coronary artery disease. The LA volumes were measured using two different methods: the two dimensional (2D) length-based (LB) method measured along the three-orthogonal planes of the LA and the 3D volumetric threshold-based (VTB) method measured according to the threshold 3D segmentation of the LA. The results obtained by cardiac MDCT were compared with those obtained by echocardiography. RESULTS: The LA end-systolic and end-diastolic volumes (LAESV and LAEDV) measured by the 2D-LB method correlated well with those measured by the 3D-VTB method using cardiac MDCT (r = 0.763, r = 0.786, p = 0.001). However, there was a significant difference in the LAESVs between the two measurement methods using cardiac MDCT (p < 0.05). The LAESV measured by cardiac MDCT correlated well with measurements by echocardiography (r = 0.864, p = 0.001), however with a significant difference (p < 0.01) in their volumes. The cardiac MDCT overestimated the LAESV by 22% compared to measurements by echocardiography. CONCLUSION: A significant correlation was found between the two different measurement methods for evaluating LA volumes by cardiac MDCT. Further, cardiac MDCT correlates well with echocardiography in evaluating the LA volume. However, there are significant differences in the LAESV between the two measurement methods using cardiac MDCT and between cardiac MDCT and echocardiography-
dc.description.statementOfResponsibilityopen-
dc.format.extent286~294-
dc.relation.isPartOfKOREAN JOURNAL OF RADIOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAdult-
dc.subject.MESHAged-
dc.subject.MESHAged, 80 and over-
dc.subject.MESHAtrial Function, Left-
dc.subject.MESHCardiac Volume*-
dc.subject.MESHContrast Media-
dc.subject.MESHCoronary Artery Disease/diagnostic imaging*-
dc.subject.MESHElectrocardiography/methods-
dc.subject.MESHFemale-
dc.subject.MESHHeart Atria/diagnostic imaging-
dc.subject.MESHHumans-
dc.subject.MESHImaging, Three-Dimensional/methods-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHObserver Variation-
dc.subject.MESHProspective Studies-
dc.subject.MESHRadiographic Image Enhancement/methods-
dc.subject.MESHTomography, X-Ray Computed/methods*-
dc.subject.MESHTriiodobenzoic Acids-
dc.subject.MESHUltrasonography-
dc.titleEvaluation of Left Atrial Volumes Using Multidetector Computed Tomography: Comparison with Echocardiography-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Internal Medicine (내과학)-
dc.contributor.googleauthorHye Mi Gweon-
dc.contributor.googleauthorSang Jin Kim-
dc.contributor.googleauthorTae Hoon Kim-
dc.contributor.googleauthorSang Min Lee-
dc.contributor.googleauthorYoo Jin Hong-
dc.contributor.googleauthorSe-Joong Rim-
dc.identifier.doi10.3348/kjr.2010.11.3.286-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00528-
dc.contributor.localIdA03372-
dc.contributor.localIdA04422-
dc.contributor.localIdA02815-
dc.contributor.localIdA01086-
dc.relation.journalcodeJ02884-
dc.identifier.eissn2005-8330-
dc.identifier.pmid20461182-
dc.subject.keywordLeft atrial volume-
dc.subject.keywordMultidetector computed tomography-
dc.subject.keyword2D and 3D measurements-
dc.subject.keywordEchocardiography-
dc.subject.keywordSimpson method-
dc.contributor.alternativeNameKim, Sang Jin-
dc.contributor.alternativeNameKim, Tae Hoon-
dc.contributor.alternativeNameLee, Sang Min-
dc.contributor.alternativeNameRim, Se Joong-
dc.contributor.alternativeNameHong, Yoo Jin-
dc.contributor.affiliatedAuthorKim, Sang Jin-
dc.contributor.affiliatedAuthorRim, Se Joong-
dc.contributor.affiliatedAuthorHong, Yoo Jin-
dc.contributor.affiliatedAuthorLee, Sang Min-
dc.contributor.affiliatedAuthorKim, Tae Hoon-
dc.citation.volume11-
dc.citation.number3-
dc.citation.startPage286-
dc.citation.endPage294-
dc.identifier.bibliographicCitationKOREAN JOURNAL OF RADIOLOGY, Vol.11(3) : 286-294, 2010-
dc.identifier.rimsid47752-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.