3 759

Cited 78 times in

Radial k-t FOCUSS for high-resolution cardiac cine MRI

DC Field Value Language
dc.contributor.author박재석-
dc.date.accessioned2015-04-23T16:21:20Z-
dc.date.available2015-04-23T16:21:20Z-
dc.date.issued2010-
dc.identifier.issn0740-3194-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/100432-
dc.description.abstractA compressed sensing dynamic MR technique called k-t FOCUSS (k-t FOCal Underdetermined System Solver) has been recently proposed. It outperforms the conventional k-t BLAST/SENSE (Broad-use Linear Acquisition Speed-up Technique/SENSitivity Encoding) technique by exploiting the sparsity of x-f signals. This paper applies this idea to radial trajectories for high-resolution cardiac cine imaging. Radial trajectories are more suitable for high-resolution dynamic MRI than Cartesian trajectories since there is smaller tradeoff between spatial resolution and number of views if streaking artifacts due to limited views can be resolved. As shown for Cartesian trajectories, k-t FOCUSS algorithm efficiently removes artifacts while preserving high temporal resolution. k-t FOCUSS algorithm applied to radial trajectories is expected to enhance dynamic MRI quality. Rather than using an explicit gridding method, which transforms radial k-space sampling data to Cartesian grid prior to applying k-t FOCUSS algorithms, we use implicit gridding during FOCUSS iterations to prevent k-space sampling errors from being propagated. In addition, motion estimation and motion compensation after the first FOCUSS iteration were used to further sparsify the residual image. By applying an additional k-t FOCUSS step to the residual image, improved resolution was achieved. In vivo experimental results show that this new method can provide high spatiotemporal resolution even from a very limited radial data set.-
dc.description.statementOfResponsibilityopen-
dc.format.extent68~78-
dc.relation.isPartOfMAGNETIC RESONANCE IN MEDICINE-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAlgorithms*-
dc.subject.MESHHeart/anatomy & histology*-
dc.subject.MESHImage Enhancement/methods*-
dc.subject.MESHImage Interpretation, Computer-Assisted/methods*-
dc.subject.MESHMagnetic Resonance Imaging,Cine/instrumentation-
dc.subject.MESHMagnetic Resonance Imaging,Cine/methods*-
dc.subject.MESHPhantoms, Imaging-
dc.subject.MESHReproducibility of Results-
dc.subject.MESHSensitivity and Specificity-
dc.subject.MESHSignal Processing, Computer-Assisted*-
dc.titleRadial k-t FOCUSS for high-resolution cardiac cine MRI-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiology (영상의학)-
dc.contributor.googleauthorHong Jung-
dc.contributor.googleauthorJaeseok Park-
dc.contributor.googleauthorJaeheung Yoo-
dc.contributor.googleauthorJong Chul Ye-
dc.identifier.doi10.1002/mrm.22172-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA01635-
dc.relation.journalcodeJ02179-
dc.identifier.eissn1522-2594-
dc.identifier.pmid19859952-
dc.identifier.urlhttp://onlinelibrary.wiley.com/doi/10.1002/mrm.22172/abstract-
dc.subject.keywordradial trajectory-
dc.subject.keyworddynamic MR imaging-
dc.subject.keywordgridding method-
dc.subject.keywordFOCUSS-
dc.subject.keywordmotion estimation and motion compensation-
dc.subject.keywordresidual encoding-
dc.contributor.alternativeNamePark, Jae Seok-
dc.contributor.affiliatedAuthorPark, Jae Seok-
dc.citation.volume63-
dc.citation.number1-
dc.citation.startPage68-
dc.citation.endPage78-
dc.identifier.bibliographicCitationMAGNETIC RESONANCE IN MEDICINE, Vol.63(1) : 68-78, 2010-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.