Metal Artifact Reduction Software Used With Abdominopelvic Dual-Energy CT of Patients With Metal Hip Prostheses: Assessment of Image Quality and Clinical Feasibility

DC Field Value Language
dc.contributor.author정용은-
dc.contributor.author김기황-
dc.contributor.author김명진-
dc.contributor.author박관규-
dc.contributor.author이영한-
dc.date.accessioned2015-01-06T17:31:34Z-
dc.date.available2015-01-06T17:31:34Z-
dc.date.issued2014-
dc.identifier.issn0361-803X-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/100142-
dc.description.abstractOBJECTIVE: The objective of our study was to determine the feasibility of using Metal Artifact Reduction (MAR) software for abdominopelvic dual-energy CT in patients with metal hip prostheses. MATERIALS AND METHODS: This retrospective study included 33 patients (male-female ratio, 19:14; mean age, 63.7 years) who received total hip replacements and 20 patients who did not have metal prostheses as the control group. All of the patients underwent dual-energy CT. The quality of the images reconstructed using the MAR algorithm and of those reconstructed using the standard reconstruction was evaluated in terms of the visibility of the bladder wall, pelvic sidewall, rectal shelf, and bone-prosthesis interface and the overall diagnostic image quality with a 4-point scale. The mean and SD attenuation values in Hounsfield units were measured in the bladder, pelvic sidewall, and rectal shelf. For validation of the MAR interpolation algorithm, pelvis phantoms with small bladder "lesions" and metal hip prostheses were made, and images of the phantoms both with and without MAR reconstruction were evaluated. RESULTS: Image quality was significantly better with MAR reconstruction than without at all sites except the rectal shelf, where the image quality either had not changed or had worsened after MAR reconstruction. The mean attenuation value was changed after MAR reconstruction to its original expected value at the pelvic sidewall (p < 0.001) and inside the bladder (p < 0.001). The SD attenuation value was significantly decreased after MAR reconstruction at the pelvic sidewall (p = 0.019) but did not show significant differences at the bladder (p = 0.173) or rectal shelf (p = 0.478). In the phantom study, all lesions obscured by metal artifacts on the standard reconstruction images were visualized after MAR reconstruction; however, new artifacts had developed in other parts of the MAR reconstruction images. CONCLUSION: The use of MAR software with dual-energy CT decreases metal artifacts and increases diagnostic confidence in the assessment of the pelvic cavity but also introduces new artifacts that can obscure pelvic structures.-
dc.description.statementOfResponsibilityopen-
dc.format.extent788~795-
dc.relation.isPartOfAMERICAN JOURNAL OF ROENTGENOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAlgorithms-
dc.subject.MESHArtifacts*-
dc.subject.MESHFeasibility Studies-
dc.subject.MESHFemale-
dc.subject.MESHHip Prosthesis*-
dc.subject.MESHHumans-
dc.subject.MESHMetals*-
dc.subject.MESHMiddle Aged-
dc.subject.MESHObserver Variation-
dc.subject.MESHPelvis/diagnostic imaging-
dc.subject.MESHRadiographic Image Enhancement/methods*-
dc.subject.MESHRadiographic Image Interpretation, Computer-Assisted/methods-
dc.subject.MESHRadiography, Abdominal/methods*-
dc.subject.MESHRadiography, Dual-Energy Scanned Projection/methods-
dc.subject.MESHReproducibility of Results-
dc.subject.MESHSensitivity and Specificity-
dc.subject.MESHSoftware*-
dc.subject.MESHTomography, X-Ray Computed/methods*-
dc.titleMetal Artifact Reduction Software Used With Abdominopelvic Dual-Energy CT of Patients With Metal Hip Prostheses: Assessment of Image Quality and Clinical Feasibility-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiology (영상의학)-
dc.contributor.googleauthorSeung Chol Han-
dc.contributor.googleauthorYong Eun Chung-
dc.contributor.googleauthorYoung Han Lee-
dc.contributor.googleauthorKwan Kyu Park-
dc.contributor.googleauthorMyeong Jin Kim-
dc.contributor.googleauthorKi Whang Kim-
dc.identifier.doi10.2214/AJR.13.10980-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA03662-
dc.contributor.localIdA00345-
dc.contributor.localIdA00426-
dc.contributor.localIdA01428-
dc.contributor.localIdA02967-
dc.relation.journalcodeJ00116-
dc.identifier.eissn1546-3141-
dc.identifier.pmid25247944-
dc.identifier.urlhttp://www.ajronline.org/doi/abs/10.2214/AJR.13.10980-
dc.subject.keywordMetal Artifact Reduction software-
dc.subject.keywordabdominal dual-energy CT-
dc.subject.keywordmetal hip prosthesis-
dc.subject.keywordpelvic cavity-
dc.subject.keywordphantom-
dc.contributor.alternativeNameChung, Yong Eun-
dc.contributor.alternativeNameKim, Ki Whang-
dc.contributor.alternativeNameKim, Myeong Jin-
dc.contributor.alternativeNamePark, Kwan Kyu-
dc.contributor.alternativeNameLee, Young Han-
dc.contributor.affiliatedAuthorChung, Yong Eun-
dc.contributor.affiliatedAuthorKim, Ki Whang-
dc.contributor.affiliatedAuthorKim, Myeong Jin-
dc.contributor.affiliatedAuthorPark, Kwan Kyu-
dc.contributor.affiliatedAuthorLee, Young Han-
dc.rights.accessRightsfree-
dc.citation.volume203-
dc.citation.number4-
dc.citation.startPage788-
dc.citation.endPage795-
dc.identifier.bibliographicCitationAMERICAN JOURNAL OF ROENTGENOLOGY, Vol.203(4) : 788-795, 2014-
dc.identifier.rimsid51704-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Orthopedic Surgery (정형외과학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.