311 725

Cited 9 times in

Early and Midterm Outcome of Redo Coronary Artery Bypass Grafting: On-Pump versus Off-Pump Bypass

Authors
 Shin Yu Rim  ;  Lee Sak  ;  Joo Hyun Chel  ;  Youn Young-Nam  ;  Kim Jong Gun  ;  Yoo Kyung-Jong 
Citation
 Korean Journal of Thoracic and Cardiovascular Surgery, Vol.47(3) : 225-232, 2014 
Journal Title
Korean Journal of Thoracic and Cardiovascular Surgery
ISSN
 2233-601X 
Issue Date
2014
Keywords
Reoperation ; Coronary artery bypass ; Coronary artery bypass, off-pump
Abstract
Background: Redo coronary artery bypass grafting (CABG) is still associated with increased morbidity and mortality as compared to the first-time operation. Further, the application of the off-pump technique to redo CABG is limited due to technical difficulties. The aim of this retrospective study was to analyze early and midterm results after redo CABG and compare the outcome of redo on-pump and off-pump CABG. Methods: From June 1996 to October 2011, elective redo CABG was performed in 32 patients. Mean age was 64.8 years (on pump 64.3 years vs. off pump 65.5 years; p=0.658), and 21 patients were male. Among these patients, 14 (43.8%) underwent on-pump CABG, and 18 (56.2%) underwent off-pump CABG. Results: Internal thoracic artery was used in 22 patients (68.8%), and total arterial revascularization was achieved in 17 patients (53.1%). The average number of distal anastomoses was 2.13, and the rate of incomplete revascularization was 43.8%. The rate of total arterial revascularization was higher in the off-pump group (14.3% vs. 83.3%, p<0.001), and the use of saphenous vein graft was more in the on-pump group (78.6% vs. 16.7%, p<0.001). Overall hospital mortality was 3.1% (n=1) and was comparable in both groups (on pump 7.1% vs. off pump 0%; p=0.249). Postoperative complications occurred in 9 patients (64.2%), and the rate of complications was high in the on-pump group without statistical significance (64.2% vs. 33.3%, p=0.082). The mean follow-up duration was 5.4 years, and overall survival at 10 years was 86.0%±10.5%. There was no significant difference in the 10-year survival rate between the two groups (79.6% vs. 100%, p=0.225). Conclusion: Redo CABG can be safely performed with acceptable mortality. Redo off-pump coronary artery bypass is feasible with low mortality and morbidity, comparable target vessel bypass grafting, and long-term survival. The off-pump technique might be considered a safe option for redo CABG in high-risk patients.
Files in This Item:
T201401893.pdf Download
DOI
10.5090/kjtcs.2014.47.3.225
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Thoracic and Cardiovascular Surgery (흉부외과학교실) > 1. Journal Papers
Yonsei Authors
Shin, Yu Rim(신유림)
Yoo, Kyung Jong(유경종) ORCID logo https://orcid.org/0000-0002-9858-140X
Youn, Young Nam(윤영남)
Lee, Sak(이삭) ORCID logo https://orcid.org/0000-0001-6130-2342
Joo, Hyun Chel(주현철) ORCID logo https://orcid.org/0000-0002-6842-2942
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/99005
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links