1 616

Cited 7 times in

Biologic evaluation of a hollow-type miniscrew implant: An experimental study in beagles

DC Field Value Language
dc.contributor.author황충주-
dc.contributor.author유형석-
dc.contributor.author차정열-
dc.date.accessioned2015-01-06T16:44:37Z-
dc.date.available2015-01-06T16:44:37Z-
dc.date.issued2014-
dc.identifier.issn0889-5406-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/98681-
dc.description.abstractINTRODUCTION: The aims of this study were to assess the biologic stability of a newly designed hollow (H-type) miniscrew compared with conventional (C-type) miniscrews through histomorphometric and histologic analysis. METHODS: Both types of miniscrews were placed into the maxillae and the mandibles of 12 beagles. Maximum insertion torque, Periotest (Siemens AG, Bensheim, Germany) value, bone-implant contact, and bone volume were measured. RESULTS: The overall success rates of the H-type were 78.3% in the maxilla and 60.0% in the mandible. Mean maximum insertion torque values of the H-type were 14.2 N-cm in the maxilla and 20.9 N-cm in the mandible. The Periotest values of the H-type were -1.5 in the maxilla and -6.4 in the mandible. Mean maximum insertion torque and Periotest values of the H-type were higher than those of the C-type. In the maxilla, the bone-implant contact values of the H-type were 37.3% and 32.3% at 3 and 12 weeks, respectively. In the mandible, the bone-implant contact values were 31.4% and 18.5% at 3 and 12 weeks, respectively. CONCLUSIONS: Considering the lower success rate and the insufficient bone-implant contact and bone volume of the H-type in the mandible, the clinician should choose a suitable combination of miniscrews depending on local bone quality and implantation site, such as an H-type in the maxilla and a C-type in the mandible.-
dc.description.statementOfResponsibilityopen-
dc.format.extent626~637-
dc.relation.isPartOfAMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAnimals-
dc.subject.MESHBone Density/physiology-
dc.subject.MESHBone Remodeling/physiology-
dc.subject.MESHBone Screws*-
dc.subject.MESHConnective Tissue/pathology-
dc.subject.MESHDogs-
dc.subject.MESHImage Processing, Computer-Assisted/methods-
dc.subject.MESHMale-
dc.subject.MESHMandible/pathology-
dc.subject.MESHMandible/surgery-
dc.subject.MESHMaxilla/pathology-
dc.subject.MESHMaxilla/surgery-
dc.subject.MESHMiniaturization-
dc.subject.MESHOrthodontic Anchorage Procedures/instrumentation*-
dc.subject.MESHOrthodontic Appliance Design*-
dc.subject.MESHOsseointegration/physiology-
dc.subject.MESHOsteoblasts/pathology-
dc.subject.MESHOsteogenesis/physiology-
dc.subject.MESHSurface Properties-
dc.subject.MESHTime Factors-
dc.subject.MESHTorque-
dc.subject.MESHVibration-
dc.titleBiologic evaluation of a hollow-type miniscrew implant: An experimental study in beagles-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Orthodontics (교정과학)-
dc.contributor.googleauthorJeong-Won Youn-
dc.contributor.googleauthorJung-Yul Cha-
dc.contributor.googleauthorHyung-Seog Yu-
dc.contributor.googleauthorChung-Ju Hwang-
dc.identifier.doi10.1016/j.ajodo.2013.12.028-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA04492-
dc.contributor.localIdA02532-
dc.contributor.localIdA04006-
dc.relation.journalcodeJ00098-
dc.identifier.eissn1097-6752-
dc.identifier.pmid24785927-
dc.identifier.urlhttp://www.sciencedirect.com/science/article/pii/S0889540614000948-
dc.contributor.alternativeNameHwang, Chung Ju-
dc.contributor.alternativeNameYu, Hyung Seog-
dc.contributor.alternativeNameCha, Jung Yul-
dc.contributor.affiliatedAuthorHwang, Chung Ju-
dc.contributor.affiliatedAuthorYu, Hyung Seog-
dc.contributor.affiliatedAuthorCha, Jung Yul-
dc.rights.accessRightsfree-
dc.citation.volume145-
dc.citation.number5-
dc.citation.startPage626-
dc.citation.endPage637-
dc.identifier.bibliographicCitationAMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, Vol.145(5) : 626-637, 2014-
dc.identifier.rimsid38534-
dc.type.rimsART-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Orthodontics (교정과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.