Cited 7 times in
Biologic evaluation of a hollow-type miniscrew implant: An experimental study in beagles
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 황충주 | - |
dc.contributor.author | 유형석 | - |
dc.contributor.author | 차정열 | - |
dc.date.accessioned | 2015-01-06T16:44:37Z | - |
dc.date.available | 2015-01-06T16:44:37Z | - |
dc.date.issued | 2014 | - |
dc.identifier.issn | 0889-5406 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/98681 | - |
dc.description.abstract | INTRODUCTION: The aims of this study were to assess the biologic stability of a newly designed hollow (H-type) miniscrew compared with conventional (C-type) miniscrews through histomorphometric and histologic analysis. METHODS: Both types of miniscrews were placed into the maxillae and the mandibles of 12 beagles. Maximum insertion torque, Periotest (Siemens AG, Bensheim, Germany) value, bone-implant contact, and bone volume were measured. RESULTS: The overall success rates of the H-type were 78.3% in the maxilla and 60.0% in the mandible. Mean maximum insertion torque values of the H-type were 14.2 N-cm in the maxilla and 20.9 N-cm in the mandible. The Periotest values of the H-type were -1.5 in the maxilla and -6.4 in the mandible. Mean maximum insertion torque and Periotest values of the H-type were higher than those of the C-type. In the maxilla, the bone-implant contact values of the H-type were 37.3% and 32.3% at 3 and 12 weeks, respectively. In the mandible, the bone-implant contact values were 31.4% and 18.5% at 3 and 12 weeks, respectively. CONCLUSIONS: Considering the lower success rate and the insufficient bone-implant contact and bone volume of the H-type in the mandible, the clinician should choose a suitable combination of miniscrews depending on local bone quality and implantation site, such as an H-type in the maxilla and a C-type in the mandible. | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 626~637 | - |
dc.relation.isPartOf | AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Animals | - |
dc.subject.MESH | Bone Density/physiology | - |
dc.subject.MESH | Bone Remodeling/physiology | - |
dc.subject.MESH | Bone Screws* | - |
dc.subject.MESH | Connective Tissue/pathology | - |
dc.subject.MESH | Dogs | - |
dc.subject.MESH | Image Processing, Computer-Assisted/methods | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Mandible/pathology | - |
dc.subject.MESH | Mandible/surgery | - |
dc.subject.MESH | Maxilla/pathology | - |
dc.subject.MESH | Maxilla/surgery | - |
dc.subject.MESH | Miniaturization | - |
dc.subject.MESH | Orthodontic Anchorage Procedures/instrumentation* | - |
dc.subject.MESH | Orthodontic Appliance Design* | - |
dc.subject.MESH | Osseointegration/physiology | - |
dc.subject.MESH | Osteoblasts/pathology | - |
dc.subject.MESH | Osteogenesis/physiology | - |
dc.subject.MESH | Surface Properties | - |
dc.subject.MESH | Time Factors | - |
dc.subject.MESH | Torque | - |
dc.subject.MESH | Vibration | - |
dc.title | Biologic evaluation of a hollow-type miniscrew implant: An experimental study in beagles | - |
dc.type | Article | - |
dc.contributor.college | College of Dentistry (치과대학) | - |
dc.contributor.department | Dept. of Orthodontics (교정과학) | - |
dc.contributor.googleauthor | Jeong-Won Youn | - |
dc.contributor.googleauthor | Jung-Yul Cha | - |
dc.contributor.googleauthor | Hyung-Seog Yu | - |
dc.contributor.googleauthor | Chung-Ju Hwang | - |
dc.identifier.doi | 10.1016/j.ajodo.2013.12.028 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A04492 | - |
dc.contributor.localId | A02532 | - |
dc.contributor.localId | A04006 | - |
dc.relation.journalcode | J00098 | - |
dc.identifier.eissn | 1097-6752 | - |
dc.identifier.pmid | 24785927 | - |
dc.identifier.url | http://www.sciencedirect.com/science/article/pii/S0889540614000948 | - |
dc.contributor.alternativeName | Hwang, Chung Ju | - |
dc.contributor.alternativeName | Yu, Hyung Seog | - |
dc.contributor.alternativeName | Cha, Jung Yul | - |
dc.contributor.affiliatedAuthor | Hwang, Chung Ju | - |
dc.contributor.affiliatedAuthor | Yu, Hyung Seog | - |
dc.contributor.affiliatedAuthor | Cha, Jung Yul | - |
dc.rights.accessRights | free | - |
dc.citation.volume | 145 | - |
dc.citation.number | 5 | - |
dc.citation.startPage | 626 | - |
dc.citation.endPage | 637 | - |
dc.identifier.bibliographicCitation | AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, Vol.145(5) : 626-637, 2014 | - |
dc.identifier.rimsid | 38534 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.