223 534

Cited 2 times in

Comparison of Full Lesion Coverage versus Spot Drug-Eluting Stent Implantation for Coronary Artery Stenoses.

Authors
 Seunghwan Kim  ;  Kyeong Ho Yun  ;  Woong Chol Kang  ;  Dong-Ho Shin  ;  Jung-Sun Kim  ;  Byeong-Keuk Kim  ;  Young-Guk Ko  ;  Donghoon Choi  ;  Yangsoo Jang  ;  Myeong-Ki Hong 
Citation
 YONSEI MEDICAL JOURNAL, Vol.55(3) : 584-591, 2014 
Journal Title
YONSEI MEDICAL JOURNAL
ISSN
 0513-5796 
Issue Date
2014
MeSH
Aged ; Coronary Stenosis/surgery* ; Drug-Eluting Stents* ; Female ; Humans ; Male ; Middle Aged ; Percutaneous Coronary Intervention/methods*
Keywords
Drug-eluting stents ; coronary artery disease ; percutaneous coronary intervention
Abstract
PURPOSE:
The aim of this study was to evaluate and compare the long-term clinical outcomes of the spot drug-eluting stent (DES) implantation strategy, which is used to minimize implanted stent length and the number of stents, versus full lesion coverage for treatment of coronary artery stenoses.
MATERIALS AND METHODS:
We evaluated 1-year clinical outcomes of 1619 patients with stent implantation for a single coronary lesion. They were divided into two groups: those treated by full lesion coverage (n=1200) and those treated with the spot stenting strategy (n=419). The combined occurrence of 1-year target vessel failure (TVF), including cardiac death, target-vessel related myocardial infarction, or ischemia-driven target-vessel revascularization was evaluated.
RESULTS:
The spot DES implantation group had a shorter stent length (23.14±9.70 mm vs. 25.44±13.24 mm, respectively; p<0.001) and a fewer number of stents (1.09±0.30 vs. 1.16±0.41, respectively; p<0.001), even though the average lesion length was similar to the full lesion coverage group (21.36±10.30 mm vs. 20.58±10.97 mm, respectively; p=0.206). Spot DES implantation was superior to full DES coverage with respect to 1-year TVF (1.4% vs. 3.3%, p=0.044). Cox proportional hazard model analysis showed that the risk for 1-year TVF was almost 60% lower among patients who received spot DESs compared to those who received full DES coverage after adjustment for other risk factors (HR=0.40, 95% confidence interval=0.17-0.98; p=0.046).
CONCLUSION:
Minimizing stent length and the number of stents with overlapping by spot DES implantation may result in reduced rates of 1-year TVF, compared with full DES coverage.
Files in This Item:
T201400874.pdf Download
DOI
10.3349/ymj.2014.55.3.584
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
Yonsei Authors
Ko, Young Guk(고영국) ORCID logo https://orcid.org/0000-0001-7748-5788
Kim, Byeong Keuk(김병극) ORCID logo https://orcid.org/0000-0003-2493-066X
Kim, Jung Sun(김중선) ORCID logo https://orcid.org/0000-0003-2263-3274
Shin, Dong Ho(신동호) ORCID logo https://orcid.org/0000-0002-7874-5542
Jang, Yang Soo(장양수) ORCID logo https://orcid.org/0000-0002-2169-3112
Choi, Dong Hoon(최동훈) ORCID logo https://orcid.org/0000-0002-2009-9760
Hong, Myeong Ki(홍명기) ORCID logo https://orcid.org/0000-0002-2090-2031
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/98432
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.