204 510

Cited 18 times in

Comparison of Higher-Order Aberration and Contrast Sensitivity in Monofocal and Multifocal Intraocular Lenses

DC Field Value Language
dc.contributor.author김태임-
dc.contributor.author서경률-
dc.date.accessioned2014-12-21T17:23:50Z-
dc.date.available2014-12-21T17:23:50Z-
dc.date.issued2007-
dc.identifier.issn0513-5796-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/97512-
dc.description.abstractPURPOSE: The visual performance of pseudophakic eyes depends on the type of intraocular lenses (IOLs) that are implanted. Aspherical and multifocal IOLs have recently been developed to improve visual quality after cataract surgery, but multifocal IOLs can be associated with decreased contrast sensitivity (CS), halos, and glare. This study compares the visual performance of monofocal and multifocal IOLs by measurement of higher-order aberrations (HOAs) and CS values. MATERIALS AND METHODS: HOAs and CS values of 42 eyes with implanted monofocal IOLs and 40 eyes with implanted multifocal IOLs were measured preoperatively and more than 6 months after surgery. In the multifocal IOL group, HOAs and CS values were also measured with addition of a trial lens of -0.5 diopter (D) to evaluate the compensatory effect on spherical aberration. RESULTS: CS values of the multifocal IOL group were significantly lower than those of the monofocal IOL group for all spatial frequencies tested (p<0.01), and the spherical aberration was significantly higher in the multifocal IOL group than in the monofocal IOL group (p<0.001). Addition of a -0.5 D lens to the multifocal IOL group decreased the difference in CS between the two groups (p=0.003). CONCLUSION: Increased spherical aberration may contribute to lower CS in the multifocal IOL group. In such cases, CS can be improved by addition of a -0.5 D lens to compensate for the spherical aberration.-
dc.description.statementOfResponsibilityopen-
dc.format.extent627~633-
dc.relation.isPartOfYONSEI MEDICAL JOURNAL-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titleComparison of Higher-Order Aberration and Contrast Sensitivity in Monofocal and Multifocal Intraocular Lenses-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Ophthalmology (안과학)-
dc.contributor.googleauthorChang Yeom Kim-
dc.contributor.googleauthorSo-Hyang Chung-
dc.contributor.googleauthorKyoung Yul Seo-
dc.contributor.googleauthorGeunyoung Yoon-
dc.contributor.googleauthorYoung Jae Cho-
dc.contributor.googleauthorTae-im Kim-
dc.identifier.doi10.3349/ymj.2007.48.4.627-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA01080-
dc.contributor.localIdA01870-
dc.relation.journalcodeJ02813-
dc.identifier.eissn1976-2437-
dc.contributor.alternativeNameKim, Tae Im-
dc.contributor.alternativeNameSeo, Kyuong Yul-
dc.contributor.affiliatedAuthorKim, Tae Im-
dc.contributor.affiliatedAuthorSeo, Kyuong Yul-
dc.rights.accessRightsfree-
dc.citation.volume48-
dc.citation.number4-
dc.citation.startPage627-
dc.citation.endPage633-
dc.identifier.bibliographicCitationYONSEI MEDICAL JOURNAL, Vol.48(4) : 627-633, 2007-
dc.identifier.rimsid57413-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.