Cited 63 times in
Central Corneal Thickness Measurements in Unoperated Eyes and Eyes After PRK For Myopia Using Pentacam, Orbscan II, and Ultrasonic Pachymetry
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김응권 | - |
dc.contributor.author | 김태임 | - |
dc.date.accessioned | 2014-12-21T16:52:45Z | - |
dc.date.available | 2014-12-21T16:52:45Z | - |
dc.date.issued | 2007 | - |
dc.identifier.issn | 1081-597X | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/96523 | - |
dc.description.abstract | PURPOSE: To compare central corneal thickness measurements obtained in unoperated eyes and eyes after myopic photorefractive keratectomy (PRK) using a rotating Scheimpflug camera (Pentacam), a scanning slit corneal topography system (Orbscan II), and ultrasonic pachymetry. METHODS: Corneal thickness was measured using Pentacam, Orbscan II, and ultrasonic pachymetry in 25 unoperated eyes (unoperated group), 24 eyes 1 to 3 months after myopic PRK (early postoperative PRK group), and 21 eyes 4 months or more after myopic PRK (late postoperative PRK group). RESULTS: In the unoperated group, corneal thickness measurements were similar for all three methods (P=.125). In the early postoperative PRK group, Orbscan measurements were thinner than Pentacam and ultrasonic measurements by a mean of 69.4 microm and 63.4 microm (P<.001 and P=.002, respectively). In the late postoperative PRK group, Orbscan measurements were thinner than Pentacam measurements by a mean of 36.0 microm (P=.017). Pentacam and ultrasonic pachymetry measurements were similar for all three groups with a mean difference of approximately 10 microm. CONCLUSIONS: Following myopic PRK, Pentacam was comparable to ultrasonic pachymetry in measuring corneal thickness, whereas Orbscan measurements were thinner. | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 888~894 | - |
dc.relation.isPartOf | JOURNAL OF REFRACTIVE SURGERY | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Adult | - |
dc.subject.MESH | Cornea/diagnostic imaging* | - |
dc.subject.MESH | Cornea/pathology* | - |
dc.subject.MESH | Corneal Topography* | - |
dc.subject.MESH | Diagnostic Techniques, Ophthalmological* | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Lasers, Excimer | - |
dc.subject.MESH | Myopia/surgery* | - |
dc.subject.MESH | Photorefractive Keratectomy* | - |
dc.subject.MESH | Postoperative Period | - |
dc.subject.MESH | Ultrasonography | - |
dc.title | Central Corneal Thickness Measurements in Unoperated Eyes and Eyes After PRK For Myopia Using Pentacam, Orbscan II, and Ultrasonic Pachymetry | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Ophthalmology (안과학) | - |
dc.contributor.googleauthor | Sun Woong Kim | - |
dc.contributor.googleauthor | Yeo Jue Byun | - |
dc.contributor.googleauthor | Tae-im Kim | - |
dc.contributor.googleauthor | Eung Kweon Kim | - |
dc.identifier.doi | 10.3928/1081-597X-20071101-04 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A00831 | - |
dc.contributor.localId | A01080 | - |
dc.relation.journalcode | J01730 | - |
dc.identifier.pmid | 18041241 | - |
dc.identifier.url | http://www.healio.com/ophthalmology/journals/jrs/2007-11-23-9/%7Bb359945e-3f1b-40e7-b297-57192d47a11a%7D/central-corneal-thickness-measurements-in-unoperated-eyes-and-eyes-after-prk-for-myopia-using-pentacam-orbscan-ii-and-ultrasonic-pachymetry | - |
dc.contributor.alternativeName | Kim, Eung Kweon | - |
dc.contributor.alternativeName | Kim, Tae Im | - |
dc.contributor.affiliatedAuthor | Kim, Eung Kweon | - |
dc.contributor.affiliatedAuthor | Kim, Tae Im | - |
dc.rights.accessRights | not free | - |
dc.citation.volume | 23 | - |
dc.citation.number | 9 | - |
dc.citation.startPage | 888 | - |
dc.citation.endPage | 894 | - |
dc.identifier.bibliographicCitation | JOURNAL OF REFRACTIVE SURGERY, Vol.23(9) : 888-894, 2007 | - |
dc.identifier.rimsid | 36138 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.