396 450

Cited 0 times in

구면/비구면 레스토렌즈와 크리스타렌즈를 삽입한 후의 시력, 구면수차, 대비감도의 비교

DC Field Value Language
dc.contributor.author김응권-
dc.contributor.author김태임-
dc.date.accessioned2014-12-20T17:36:08Z-
dc.date.available2014-12-20T17:36:08Z-
dc.date.issued2011-
dc.identifier.issn0378-6471-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/94911-
dc.description.abstractPURPOSE: To assess visual acuity, spherical aberration and contrast sensitivity in patients who were implanted with spheric, aspheric ReSTOR(R) or Crystalens HD(R) lenses. METHODS: The present study enrolled 16 patients (32 eyes) implanted with biliateral spheric ReSTOR(R) (four patients, spheric ReSTOR group), bilateral aspheric ReSTOR(R) (seven patients, aspheric ReSTOR group) or bilateral Crystalens HD(R) (five patients, Crystalens HD group) lenses. At three months postoperatively, visual acuity, spherical aberration, and contrast sensitivity were evaluated. RESULTS: Three months after surgery, there were no significant differences in uncorrected distant or intermediate visual acuity among the three groups. Uncorrected near visual acuity in the spheric and aspheric ReSTOR groups was superior to that in the Crystalens HD group, and the aspheric ReSTOR group had less spherical aberration. Mesopic contrast sensitivity in the Crystalens HD group was significantly higher at three cycles per degree compared to those in the spheric and aspheric ReSTOR groups. CONCLUSIONS: Uncorrected near visual acuity in the Crystalens HD group was inferior to those in the spheric and aspheric ReSTOR groups, but the mesopic contrast sensitivity of the Crystalens HD group at three cycles per degree was superior to those in the spheric and aspheric ReSTOR groups-
dc.description.statementOfResponsibilityopen-
dc.format.extent1275~1280-
dc.relation.isPartOfJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title구면/비구면 레스토렌즈와 크리스타렌즈를 삽입한 후의 시력, 구면수차, 대비감도의 비교-
dc.title.alternativeComparisons of Visual Acuity, Spherical Aberration and Contrast Sensitivity among Spheric, Aspheric ReSTOR(R), and Crystalens HD(R) Lenses-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Ophthalmology (안과학)-
dc.contributor.googleauthor강의천-
dc.contributor.googleauthor김응권-
dc.contributor.googleauthor김태임-
dc.identifier.doi10.3341/jkos.2011.52.11.1275-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00831-
dc.contributor.localIdA01080-
dc.relation.journalcodeJ01838-
dc.identifier.eissn2092-9374-
dc.subject.keywordAccommodative-
dc.subject.keywordAspheric-
dc.subject.keywordDiffractive-
dc.subject.keywordMultifocal-
dc.subject.keywordSpheric-
dc.contributor.alternativeNameKim, Eung Kweon-
dc.contributor.alternativeNameKim, Tae Im-
dc.contributor.affiliatedAuthorKim, Eung Kweon-
dc.contributor.affiliatedAuthorKim, Tae Im-
dc.rights.accessRightsfree-
dc.citation.volume52-
dc.citation.number11-
dc.citation.startPage1275-
dc.citation.endPage1280-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, Vol.52(11) : 1275-1280, 2011-
dc.identifier.rimsid27846-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.