Cited 16 times in
The effect of fibronectin-coated implant on canine osseointegration
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김성태 | - |
dc.contributor.author | 이중석 | - |
dc.contributor.author | 정의원 | - |
dc.contributor.author | 최성호 | - |
dc.date.accessioned | 2014-12-20T17:26:34Z | - |
dc.date.available | 2014-12-20T17:26:34Z | - |
dc.date.issued | 2011 | - |
dc.identifier.issn | 2093-2278 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/94611 | - |
dc.description.abstract | PURPOSE: The purpose of this study was to characterize the osseointegration of the fibronectin-coated implant surface. METHODS: Sand-blasted, large-grit, acid-etched (SLA) surface implants, with or without a thin calcium phosphate and fibronectin coating, were placed in edentulous mandibles of dogs 8 weeks after extraction. All dogs were sacrificed forhistological and histomorphometric evaluation after 4- and 8-week healing periods. RESULTS: All types of implants were clinically stable without any mobility. Although the bone-to-implant contact and bone density of the SLA implants coated with calcium phosphate (CaP)/fibronectin were lower than the uncoated SLA implants, there were no significant differences between the uncoated SLA surface group and the SLA surface coated with CaP/fibronectin group. CONCLUSIONS: Within the limits of this study, SLA surfaces coated with CaP/fibronectin were shown to have comparable bone-to-implant contact and bone density to uncoated SLA surfaces. | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 242~247 | - |
dc.relation.isPartOf | JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.title | The effect of fibronectin-coated implant on canine osseointegration | - |
dc.type | Article | - |
dc.contributor.college | College of Dentistry (치과대학) | - |
dc.contributor.department | Dept. of Prosthodontics (보철과학) | - |
dc.contributor.googleauthor | Sungtae Kim | - |
dc.contributor.googleauthor | Woo-Chun Myung | - |
dc.contributor.googleauthor | Jung-Seok Lee | - |
dc.contributor.googleauthor | Jae-Kook Cha | - |
dc.contributor.googleauthor | Ui-Won Jung | - |
dc.contributor.googleauthor | Hyeong-Cheol Yang | - |
dc.contributor.googleauthor | In-Seop Lee | - |
dc.contributor.googleauthor | Seong-Ho Choi | - |
dc.identifier.doi | 10.5051/jpis.2011.41.5.242 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A00587 | - |
dc.contributor.localId | A03692 | - |
dc.contributor.localId | A03185 | - |
dc.contributor.localId | A04081 | - |
dc.relation.journalcode | J01695 | - |
dc.identifier.eissn | 2093-2286 | - |
dc.identifier.pmid | 22087415 | - |
dc.subject.keyword | Biocompatible coated materials | - |
dc.subject.keyword | Bone density | - |
dc.subject.keyword | Calcium phosphate | - |
dc.subject.keyword | Dental implants | - |
dc.subject.keyword | Fibronectins | - |
dc.contributor.alternativeName | Kim, Sung Tae | - |
dc.contributor.alternativeName | Lee, Jung Seok | - |
dc.contributor.alternativeName | Jung, Ui Won | - |
dc.contributor.alternativeName | Choi, Seong Ho | - |
dc.contributor.affiliatedAuthor | Kim, Sung Tae | - |
dc.contributor.affiliatedAuthor | Jung, Ui Won | - |
dc.contributor.affiliatedAuthor | Lee, Jung Seok | - |
dc.contributor.affiliatedAuthor | Choi, Seong Ho | - |
dc.rights.accessRights | free | - |
dc.citation.volume | 41 | - |
dc.citation.number | 5 | - |
dc.citation.startPage | 242 | - |
dc.citation.endPage | 247 | - |
dc.identifier.bibliographicCitation | JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, Vol.41(5) : 242-247, 2011 | - |
dc.identifier.rimsid | 27452 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.