4 493

Cited 81 times in

Clinical outcomes and risk factors for technical and clinical failures of self-expandable metal stent insertion for malignant colorectal obstruction.

Authors
 Jin Young Yoon  ;  Yoon Suk Jung  ;  Sung Pil Hong  ;  Tae Il Kim  ;  Won Ho Kim  ;  Jae Hee Cheon 
Citation
 GASTROINTESTINAL ENDOSCOPY, Vol.74(4) : 858-868, 2011 
Journal Title
GASTROINTESTINAL ENDOSCOPY
ISSN
 0016-5107 
Issue Date
2011
MeSH
Adult ; Aged ; Aged ; 80 and over ; Colonoscopy ; ColorectalNeoplasms/complications* ; Female ; Humans ; IntestinalObstruction/etiology ; IntestinalObstruction/therapy* ; Male ; Middle Aged ; Palliative Care ; RiskFactors ; Stents*/adverse effects ; Treatment Failure ; Young Adult
Abstract
BACKGROUND: Although self-expandable metal stent (SEMS) insertion is widely used for relief of malignant colorectal obstructions, the immediate technical and clinical failure rates of SEMSs and the associated risk factors remain largely unknown.

OBJECTIVE: To identify rates and factors predictive of technical and clinical failure of SEMSs when their use is attempted for the decompression of malignant colorectal obstruction.

DESIGN: Retrospective chart review.

SETTING: A tertiary-care academic medical center in South Korea.

PATIENTS: This study involved a total of 412 patients with malignant colorectal obstruction in whom SEMS insertion was attempted.

INTERVENTION: Placement of colonic SEMSs.

MAIN OUTCOME MEASUREMENTS: Technical success and immediate and long-term clinical success rates.

RESULTS: Technical and clinical failures were found in 36 of 276 patients (13.0%) and 39 of 240 patients (16.3%) in the palliative group, respectively, and in 3 of 136 patients (2.2%) and 7 of 133 patients (5.3%) in the preoperative group, respectively. Factors associated with technical failure were extracolonic origin of tumor, the presence of carcinomatosis, and a proximal obstruction site. Factors associated with long-term clinical failure in the palliative group were combined dilation procedure, no additional chemotherapy, and extracolonic origin of the tumor. In the preoperative group, only older patients had both higher technical failure and clinical failure rates.

LIMITATIONS: This was a single-institution, retrospective analysis.

CONCLUSION: Although colorectal SEMS placement is generally safe and effective, it is associated with clinically important technical and clinical failure rates. The identification of risk factors for the failure of colorectal SEMSs found in this study might help physicians decide between surgical decompression and endoscopic stenting in patients with malignant colorectal obstruction.
Full Text
http://www.sciencedirect.com/science/article/pii/S0016510711017718
DOI
10.1016/j.gie.2011.05.044
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Won Ho(김원호) ORCID logo https://orcid.org/0000-0002-5682-9972
Kim, Tae Il(김태일) ORCID logo https://orcid.org/0000-0003-4807-890X
Yoon, Jin Young(윤진영)
Jung, Yoon Suk(정윤숙)
Cheon, Jae Hee(천재희) ORCID logo https://orcid.org/0000-0002-2282-8904
Hong, Sung Pil(홍성필)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/94302
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links