580 631

Cited 1 times in

III급 부정교합 환자에서 초탄성 Ni-Ti alloy wire를 이용한 비발치 치료

DC Field Value Language
dc.contributor.author정주령-
dc.contributor.author차정열-
dc.contributor.author황충주-
dc.date.accessioned2014-12-20T17:12:47Z-
dc.date.available2014-12-20T17:12:47Z-
dc.date.issued2011-
dc.identifier.issn2234-7518-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/94170-
dc.description.abstractNonextraction camouflage treatment in mild Class III malocclusion is achieved by backward movement of the lower dentition and forward movement of the upper dentition. Many camouflage treatment modalities have been used for distal tipping and distal movement of mandibular posterior teeth. The amount of distal movement of mandibular dentition can be improved in cases of severe crowding, even without the patient’s cooperation, by using miniscrews for anchorage. However, miniscrew insertion may be unsuccessful, and it may contact the adjacent root because of the distal movement of dentition. Distal tipping of mandibular dentition can be achieved using multiloop edgewise archwires and intermaxillary elastics. However, the complexity of this wire design causes discomfort to patients. Recently, a new treatment using improved superelastic NiTi wires (ISWs) and intermaxillary elastics has been introduced. ISWs can deliver orthodontic force more effectively, and their use with molar tip-back treatment has several advantages—this approach is effective, simple, and easy to use and reduces patient discomfort. The aim of this study was to report a case of camouflage treatment using ISW with tip-back and intermaxillary elastics for distal tipping of mandibular posterior dentition and to evaluate the effectiveness of this treatment in a clinical setting.-
dc.description.statementOfResponsibilityopen-
dc.format.extent297~306-
dc.relation.isPartOfKOREAN JOURNAL OF ORTHODONTICS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titleIII급 부정교합 환자에서 초탄성 Ni-Ti alloy wire를 이용한 비발치 치료-
dc.title.alternativeNon-extraction treatment in Class III malocclusion by using improved superelastic NiTi wire-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Orthodontics (교정과학)-
dc.contributor.googleauthor민 샘-
dc.contributor.googleauthor정주령-
dc.contributor.googleauthor황충주-
dc.contributor.googleauthor차정열-
dc.identifier.doi10.4041/kjod.2011.41.4.297-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA03724-
dc.contributor.localIdA04006-
dc.contributor.localIdA04492-
dc.relation.journalcodeJ02087-
dc.identifier.eissn2005-372X-
dc.subject.keywordIII급 부정교합 치료-
dc.subject.keyword치아의 후방이동-
dc.subject.keyword초탄성 Ni-Ti alloy wire-
dc.subject.keyword발치 vs. 비발치-
dc.contributor.alternativeNameChung, Choo Ryung-
dc.contributor.alternativeNameCha, Jung Yul-
dc.contributor.alternativeNameHwang, Chung Ju-
dc.contributor.affiliatedAuthorChung, Choo Ryung-
dc.contributor.affiliatedAuthorCha, Jung Yul-
dc.contributor.affiliatedAuthorHwang, Chung Ju-
dc.rights.accessRightsfree-
dc.citation.volume41-
dc.citation.number4-
dc.citation.startPage297-
dc.citation.endPage306-
dc.identifier.bibliographicCitationKOREAN JOURNAL OF ORTHODONTICS, Vol.41(4) : 297-306, 2011-
dc.identifier.rimsid27286-
dc.type.rimsART-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Orthodontics (교정과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.