771 614

Cited 0 times in

비구면 인공수정체와 구면 인공수정체의 술 후 Nd:YAG 레이저 후낭절개술 시행률 비교

DC Field Value Language
dc.contributor.author김응권-
dc.contributor.author김태임-
dc.contributor.author서경률-
dc.contributor.author전익현-
dc.date.accessioned2014-12-20T16:37:36Z-
dc.date.available2014-12-20T16:37:36Z-
dc.date.issued2011-
dc.identifier.issn0378-6471-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/93071-
dc.description.abstractPURPOSE: The purpose of the present study is to compare Nd:YAG capsulotomy rates between spherical and aspheric intraocular lenses. METHODS: The present retrospective study enrolled patients who received cataract surgery by a single surgeon between March 1, 2006 and October 31, 2009. Patients included in the study were implanted with SA60AT spherical intraocular lenses (Alcon, Fort Worth, TX, USA, 66 eyes), SN60AT spherical intraocular lenses (Alcon, 48 eyes; a total of 114 eyes), or SN60WF aspheric intraocular lenses (Alcon, 187 eyes). The Nd:YAG capsulotomy rates were compared between the two groups 6 months after the operation. Ten patients who were implanted with a spherical intraocular lens in one eye and an aspheric intraocular lens in the contralateral eye were analyzed separately. RESULTS: Nd:YAG capsulotomy was performed in 2 of 114 eyes (1.8%) in the spherical intraocular lens group and 7 of 187 eyes (3.2%) in the aspheric intraocular lens group; no significant difference was found (p = 0.359). Among the 10 patients who were implanted with 2 different intraocular lenses, Nd:YAG capsulotomy was performed in only 1 eye in the aspheric intraocular lens group; no significant difference was found (p = 0.500). CONCLUSIONS: The design of the intraocular lens, especially the shape of the posterior optic, does not influence the rate of Nd:YAG capsulotomy-
dc.description.statementOfResponsibilityopen-
dc.format.extent414~419-
dc.relation.isPartOfJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title비구면 인공수정체와 구면 인공수정체의 술 후 Nd:YAG 레이저 후낭절개술 시행률 비교-
dc.title.alternativeComparison of Nd:YAG Capsulotomy Rates between Spherical and Aspheric Intraocular Lenses.-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Ophthalmology (안과학)-
dc.contributor.googleauthor전익현-
dc.contributor.googleauthor서경률-
dc.contributor.googleauthor김응권-
dc.contributor.googleauthor김태임-
dc.identifier.doi10.3341/jkos.2011.52.4.414-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00831-
dc.contributor.localIdA01080-
dc.contributor.localIdA01870-
dc.contributor.localIdA03541-
dc.relation.journalcodeJ01838-
dc.identifier.eissn2092-9374-
dc.subject.keywordAspheric-
dc.subject.keywordNd:YAG capsulotomy-
dc.subject.keywordOptic design-
dc.subject.keywordPosterior capsule opacification-
dc.subject.keywordSpherical-
dc.contributor.alternativeNameKim, Eung Kweon-
dc.contributor.alternativeNameKim, Tae Im-
dc.contributor.alternativeNameSeo, Kyuong Yul-
dc.contributor.affiliatedAuthorKim, Eung Kweon-
dc.contributor.affiliatedAuthorKim, Tae Im-
dc.contributor.affiliatedAuthorSeo, Kyuong Yul-
dc.contributor.affiliatedAuthorJun, Ik Hyun-
dc.rights.accessRightsfree-
dc.citation.volume52-
dc.citation.number4-
dc.citation.startPage414-
dc.citation.endPage419-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, Vol.52(4) : 414-419, 2011-
dc.identifier.rimsid28010-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.