Cited 39 times in
Comparison of goldmann applanation tonometer, noncontact tonometer, and TonoPen XL for intraocular pressure measurement in different types of glaucomatous, ocular hypertensive, and normal eyes.
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김나래 | - |
dc.contributor.author | 김찬윤 | - |
dc.contributor.author | 성공제 | - |
dc.contributor.author | 이은석 | - |
dc.date.accessioned | 2014-12-20T16:29:14Z | - |
dc.date.available | 2014-12-20T16:29:14Z | - |
dc.date.issued | 2011 | - |
dc.identifier.issn | 0271-3683 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/92807 | - |
dc.description.abstract | PURPOSE: To compare intraocular pressure (IOP) measurements by Goldmann applanation tonometer (GAT), noncontact tonometer (NCT), and TonoPen XL in glaucomatous, ocular hypertensive (OHT), and normal eyes, all with various central corneal thickness (CCT). METHODS: In 508 subjects, IOP was measured by three different tonometers: GAT, NCT, and TonoPen. CCT was also measured. RESULTS: There was a statistically significant difference between IOP measurements made using the three different tonometers (RMANOVA, P < 0.0001). Both NCT/GAT and TonoPen/GAT differences were significantly associated with age, CCT, IOP, and glaucoma diagnosis (multiple regression analysis, all P ≤ 0.05). CCT and IOP had the greatest effect on IOP measurement variance by different tonometers. IOP measurements made by NCT were consistently higher than those made by GAT; this difference increased both with IOP and CCT levels, but decreased with age and OHT. In addition, TonoPen overestimated the GAT in the eyes of subjects with OHT. CONCLUSION: IOP measurement differences between the three tonometers are affected by age, type of glaucoma, and especially CCT and IOP levels. | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 295~300 | - |
dc.relation.isPartOf | CURRENT EYE RESEARCH | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Adolescent | - |
dc.subject.MESH | Adult | - |
dc.subject.MESH | Aged | - |
dc.subject.MESH | Aged, 80 and over | - |
dc.subject.MESH | Child | - |
dc.subject.MESH | Cornea/anatomy & histology | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Glaucoma, Open-Angle/diagnosis* | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Intraocular Pressure/physiology* | - |
dc.subject.MESH | Low Tension Glaucoma/diagnosis | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Middle Aged | - |
dc.subject.MESH | Observer Variation | - |
dc.subject.MESH | Ocular Hypertension/diagnosis | - |
dc.subject.MESH | Tonometry, Ocular/instrumentation* | - |
dc.title | Comparison of goldmann applanation tonometer, noncontact tonometer, and TonoPen XL for intraocular pressure measurement in different types of glaucomatous, ocular hypertensive, and normal eyes. | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Ophthalmology (안과학) | - |
dc.contributor.googleauthor | Na Rae Kim | - |
dc.contributor.googleauthor | Chan Yun Kim | - |
dc.contributor.googleauthor | Hyunjoong Kim | - |
dc.contributor.googleauthor | Gong Je Seong | - |
dc.contributor.googleauthor | Eun Suk Lee | - |
dc.identifier.doi | 10.3109/02713683.2010.542865 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A03036 | - |
dc.contributor.localId | A00347 | - |
dc.contributor.localId | A01035 | - |
dc.contributor.localId | A01946 | - |
dc.relation.journalcode | J00665 | - |
dc.identifier.eissn | 1460-2202 | - |
dc.identifier.pmid | 21284505 | - |
dc.identifier.url | http://informahealthcare.com/doi/abs/10.3109/02713683.2010.542865 | - |
dc.subject.keyword | Central corneal thickness | - |
dc.subject.keyword | Glaucoma | - |
dc.subject.keyword | Goldmann applanation tonometer | - |
dc.subject.keyword | Noncontact tonometer | - |
dc.subject.keyword | TonoPen | - |
dc.contributor.alternativeName | Kim, Na Rae | - |
dc.contributor.alternativeName | Kim, Chan Yun | - |
dc.contributor.alternativeName | Seong, Gong Je | - |
dc.contributor.alternativeName | Lee, Eun Suk | - |
dc.contributor.affiliatedAuthor | Lee, Eun Suk | - |
dc.contributor.affiliatedAuthor | Kim, Na Rae | - |
dc.contributor.affiliatedAuthor | Kim, Chan Yun | - |
dc.contributor.affiliatedAuthor | Seong, Gong Je | - |
dc.rights.accessRights | not free | - |
dc.citation.volume | 36 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 295 | - |
dc.citation.endPage | 300 | - |
dc.identifier.bibliographicCitation | CURRENT EYE RESEARCH, Vol.36(4) : 295-300, 2011 | - |
dc.identifier.rimsid | 28770 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.