Cited 0 times in
PDP공정을 이용한 가스 방식의 디지털 X-ray 영상 센서
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 남기창 | - |
dc.date.accessioned | 2014-12-19T18:00:27Z | - |
dc.date.available | 2014-12-19T18:00:27Z | - |
dc.date.issued | 2012 | - |
dc.identifier.issn | 2287-5026 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/92469 | - |
dc.description.abstract | Parallel-plate-type scanning sensors have been commercially used for X-ray imaging sensors. In this study, we manufactured the scan typed 1D X-ray image sensor that can be used to obtain scanning images, by using the plasma display panel (PDP) fabrication process. We fabricated drift and pixel electrodes in the glass chamber and injected Xe gas at atmospheric pressure. We evaluated the intensity of a pixel signal depending on the bias voltage on the drift electrode and investigated the characteristics of shielding effect on the single pixel using lead (Pb). The adsorption rate of X-ray photon is low (4%) on the soda lime glass (1.1㎜) and the electrical signal detected on the X-ray sensor was increased in the high bias voltage. We acquired digital X-ray scanning image with our DAS (data acquisition system) and sensor scanning system. | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 322~327 | - |
dc.relation.isPartOf | Journal of the Institute of Electronics and Information Engineers of Korea (전자공학회논문지) | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.title | PDP공정을 이용한 가스 방식의 디지털 X-ray 영상 센서 | - |
dc.title.alternative | Gas Typed Digital X-ray Image Sensor Using PDP Fabrication Process | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Medical Engineering (의학공학) | - |
dc.contributor.googleauthor | 김창만 | - |
dc.contributor.googleauthor | 김시형 | - |
dc.contributor.googleauthor | 남기창 | - |
dc.contributor.googleauthor | 김상희 | - |
dc.contributor.googleauthor | 송광섭 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A01242 | - |
dc.relation.journalcode | J01784 | - |
dc.identifier.pmid | 디지털 영상 센서 ; X-ray 영상 센서 ; 가스 방식 영상 센서 ; 스캔 방식 영상 센서 ; PDP | - |
dc.subject.keyword | 디지털 영상 센서 | - |
dc.subject.keyword | X-ray 영상 센서 | - |
dc.subject.keyword | 가스 방식 영상 센서 | - |
dc.subject.keyword | 스캔 방식 영상 센서 | - |
dc.subject.keyword | PDP | - |
dc.contributor.alternativeName | Nam, Ki Chang | - |
dc.contributor.affiliatedAuthor | Nam, Ki Chang | - |
dc.citation.volume | 49 | - |
dc.citation.number | 9 | - |
dc.citation.startPage | 322 | - |
dc.citation.endPage | 327 | - |
dc.identifier.bibliographicCitation | Journal of the Institute of Electronics and Information Engineers of Korea (전자공학회논문지), Vol.49(9) : 322-327, 2012 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.