dc.description.abstractTo diagnose dental pulp vitality, electric pulp tester has been widely used, which is a method to test condition of nerve. However, especially in the case of patients with trauma, nerve desensitization could temporarily occur even though nerve might be recovered by blood flow within the pulp later, which implies that blood flow in dental pulp is also an important factor for diagnosing vitality. This paper described the development of a probe that relatively measured blood flow in dental pulp using photoplethysmography (PPG). The probe emits four different wavelength light sources including three visible and an infrared light. We tested which light source detect sensitively the blood flow in dental pulp. As a result, green light had the largest peak to peak voltage and the power spectrum among different wavelengths.-
dc.description.statementOfResponsibilityopen-
dc.format.extent1204~1209-
dc.relation.isPartOfTransactions of the Korean Institute of Electrical Engineers (전기학회논문지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title치수혈류 측정을 위한 광 프로브 개발-
dc.title.alternativeDevelopment of an Optical Probe for Measuring Blood Flow in Dental Pulp-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Medical Engineering (의학공학)-
dc.contributor.googleauthor장경환-
dc.contributor.googleauthor최준열-
dc.contributor.googleauthor구정모-
dc.contributor.googleauthor권민경-
dc.contributor.googleauthor김덕원-
dc.identifier.doi10.5370/KIEE.2012.61.8.1204-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00200-
dc.contributor.localIdA00216-
dc.contributor.localIdA00376-
dc.contributor.localIdA03422-
dc.contributor.localIdA04190-
dc.relation.journalcodeJ02748-
dc.identifier.pmidDental pulp ; Vitality ; Blood flow ; Photoplethysmography ; Probe-
dc.subject.keywordDental pulp-
dc.subject.keywordVitality-
dc.subject.keywordBlood flow-
dc.subject.keywordPhotoplethysmography-
dc.subject.keywordProbe-
dc.contributor.alternativeNameKoo, Jeong Mo-
dc.contributor.alternativeNameKwon, Min Kyung-
dc.contributor.alternativeNameKim, Deok Won-
dc.contributor.alternativeNameJang, Kyung Hwan-
dc.contributor.alternativeNameChoi, Joon Yul-
dc.contributor.affiliatedAuthorKoo, Jeong Mo-
dc.contributor.affiliatedAuthorKwon, Min Kyung-
dc.contributor.affiliatedAuthorKim, Deok Won-
dc.contributor.affiliatedAuthorJang, Kyung Hwan-
dc.contributor.affiliatedAuthorChoi, Joon Yul-
dc.citation.volume61-
dc.citation.number8-
dc.citation.startPage1204-
dc.citation.endPage1209-
dc.identifier.bibliographicCitationTransactions of the Korean Institute of Electrical Engineers (전기학회논문지), Vol.61(8) : 1204-1209, 2012-
dc.identifier.rimsid31346-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Medical Engineering (의학공학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.