Cited 0 times in
U-헬스케어 응용을 위한 전도성 섬유 심전도 전극의 섬유적 특성 시험 연구
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 유선국 | - |
dc.date.accessioned | 2014-12-19T18:00:14Z | - |
dc.date.available | 2014-12-19T18:00:14Z | - |
dc.date.issued | 2012 | - |
dc.identifier.issn | 1976-7102 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/92464 | - |
dc.description.abstract | The combination of developed medical devices and the convergence of IT fusion technologies, health variables became to can be measured without discomfort in everyday life regardless of wherever and whenever. because various types of u-Health medical devices have been developed. Also, by considering the users, biological signals can be measured without difference with wearing general clothing, that conductive fabric is being used as smart clothing. However, considering that there is a growing prevalence of the devices and a great interest in the development of u-Health devices, it is urgent to establish performance evaluation. Accordingly, writing guidelines by force to raise checking before marketed or collecting checks after at the market for standard test methods for evaluating the performance. In this paper, it was studied that the possibility of using conductive fabric as electrodes for Wearable u-Health Devices through the material test of the ffabric. | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 31~41 | - |
dc.relation.isPartOf | Journal of Rehabilitation Welfare Engineering & Assistive Technology (재활복지공학회논문지) | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.title | U-헬스케어 응용을 위한 전도성 섬유 심전도 전극의 섬유적 특성 시험 연구 | - |
dc.title.alternative | A Study on Fabric Material Test of Conductive-Fabric Type ECG Electrode for u-Healthcare Application | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Medical Engineering (의학공학) | - |
dc.contributor.googleauthor | 강보규 | - |
dc.contributor.googleauthor | 황인호 | - |
dc.contributor.googleauthor | 유선국 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A02471 | - |
dc.relation.journalcode | J01734 | - |
dc.identifier.pmid | Conductive Fabric ; ECG Electrode ; Material Test ; u-Healthcare | - |
dc.identifier.url | http://www.dbpia.co.kr/Journal/ArticleDetail/3112479 | - |
dc.subject.keyword | Conductive Fabric | - |
dc.subject.keyword | ECG Electrode | - |
dc.subject.keyword | Material Test | - |
dc.subject.keyword | u-Healthcare | - |
dc.contributor.alternativeName | Yoo, Sun Kook | - |
dc.contributor.affiliatedAuthor | Yoo, Sun Kook | - |
dc.citation.volume | 6 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 31 | - |
dc.citation.endPage | 41 | - |
dc.identifier.bibliographicCitation | Journal of Rehabilitation Welfare Engineering & Assistive Technology (재활복지공학회논문지), Vol.6(2) : 31-41, 2012 | - |
dc.identifier.rimsid | 31345 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.