407 595

Cited 0 times in

삼체형과 일체형 비구면 인공수정체 삽입 후 전방부 계측치와 굴절력의 비교

DC Field Value Language
dc.contributor.author김응권-
dc.contributor.author김태임-
dc.contributor.author김혜선-
dc.date.accessioned2014-12-19T17:54:38Z-
dc.date.available2014-12-19T17:54:38Z-
dc.date.issued2012-
dc.identifier.issn0378-6471-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/92288-
dc.description.abstractPurpose: To compare the anterior chamber depth (ACD), anterior chamber volume (ACV), anterior chamber angle (ACA) and refractive change after cataract surgery between 3-piece and 1-piece aspheric intraocular lens (IOL) implantation. Methods: The present study consisted of 16 patients (25 eyes) having 3-piece aspheric Tecnis® ZA9003 IOL and 21 patients (30 eyes) having 1-piece aspheric Tecnis® ZCB00 IOL. The ACD, ACV, and ACA were measured using an anterior eye segment analysis system (Pentacam, Oculus, Wetzlar, Germany) preoperatively and postoperatively 1 week and 1 month. Refractive outcomes were evaluated using an autokeratometer. Results: When comparing the 3-piece (Tecnis® ZA9003) and 1-piece (Tecnis® ZCB00) IOL with the same optic, ACD, ACV, and AVA increased significantly after cataract surgery. The 1-piece IOL showed deeper ACD than the 3-piece IOL at postoperative 1 week and 1 month. Postoperative refraction showed slight myopic shift compared with target diopter, but was stable in both groups. Conclusions: There was significant increase in ACD, ACV, and ACA after cataract surgery in both IOL-inserted groups. Results showed stable refraction after cataract surgery in both groups. Consideration of the A-constant will be needed because of myopic change with the 1-piece IOL.-
dc.description.statementOfResponsibilityopen-
dc.relation.isPartOfJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title삼체형과 일체형 비구면 인공수정체 삽입 후 전방부 계측치와 굴절력의 비교-
dc.title.alternativeComparison of Anterior Chamber Parameter and Refractive Change between Three-Piece and Single-Piece Aspheric Intraocular Lenses-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Ophthalmology (안과학)-
dc.contributor.googleauthor김혜선-
dc.contributor.googleauthor이동민-
dc.contributor.googleauthor안지민-
dc.contributor.googleauthor김응권-
dc.contributor.googleauthor김태임-
dc.identifier.doi10.3341/jkos.2012.53.12.1789-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA01173-
dc.contributor.localIdA00831-
dc.contributor.localIdA01080-
dc.relation.journalcodeJ01838-
dc.identifier.eissn2092-9374-
dc.identifier.pmidAnterior chamber depth ; Aspheric IOL ; Refraction ; TecnisⓇ ZA9003 ; TecnisⓇ ZCB00-
dc.subject.keywordAnterior chamber depth-
dc.subject.keywordAspheric IOL-
dc.subject.keywordRefraction-
dc.subject.keywordTecnisⓇ ZA9003-
dc.subject.keywordTecnisⓇ ZCB00-
dc.contributor.alternativeNameKim, Eung Kweon-
dc.contributor.alternativeNameKim, Tae Im-
dc.contributor.alternativeNameKim, Hye Sun-
dc.contributor.affiliatedAuthorKim, Hye Sun-
dc.contributor.affiliatedAuthorKim, Eung Kweon-
dc.contributor.affiliatedAuthorKim, Tae Im-
dc.citation.volume53-
dc.citation.number12-
dc.citation.startPage1789-
dc.citation.endPage1793-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, Vol.53(12) : 1789-1793, 2012-
dc.identifier.rimsid29389-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.