Cited 0 times in
비구면 일체형 인공수정체 삽입 후 동공 크기가 시력에 미치는 영향
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김응권 | - |
dc.contributor.author | 김태임 | - |
dc.contributor.author | 서경률 | - |
dc.contributor.author | 안지민 | - |
dc.contributor.author | 이형근 | - |
dc.contributor.author | 정세환 | - |
dc.contributor.author | 한경은 | - |
dc.contributor.author | 한진우 | - |
dc.date.accessioned | 2014-12-19T17:54:36Z | - |
dc.date.available | 2014-12-19T17:54:36Z | - |
dc.date.issued | 2012 | - |
dc.identifier.issn | 0378-6471 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/92287 | - |
dc.description.abstract | Purpose: To evaluate the influence of pupil size on uncorrected visual acuity and spherical aberration of the TECNIS 1-piece intraocular lens (IOL). Methods: In this study 61 eyes were implanted with a TECNIS 1-piece IOL. Pupil size was checked by standard pupil card with cobalt blue light postoperatively. Best corrected visual acuity (BCVA) and uncorrected visual acuity (UCVA) were assessed postoperatively. Total spherical aberration and high-order aberration for mesopic pupil size zone were measured. Results: There were no significant differences of spherical equivalent, age, preoperative astigmatism, BCVA between two groups, but small pupil group revealed better UCVA (p = 0.02) and lower ocular aberration than large pupil group. Conclusions: After cataract surgery, pupil size greater than 5.0 mm increases total aberration. Thus, visual acuity with small pupil after aspheric TECNIS 1-piece IOL implantation show better clinical result on uncorrected visual acuity. | - |
dc.description.statementOfResponsibility | open | - |
dc.relation.isPartOf | JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.title | 비구면 일체형 인공수정체 삽입 후 동공 크기가 시력에 미치는 영향 | - |
dc.title.alternative | Influence of Pupil Size on Visual Acuity after Implantation of the TECNIS 1-Piece Intraocular Lens | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Ophthalmology (안과학) | - |
dc.contributor.googleauthor | 한진우 | - |
dc.contributor.googleauthor | 한경은 | - |
dc.contributor.googleauthor | 안지민 | - |
dc.contributor.googleauthor | 정세환 | - |
dc.contributor.googleauthor | 이형근 | - |
dc.contributor.googleauthor | 서경률 | - |
dc.contributor.googleauthor | 김응권 | - |
dc.contributor.googleauthor | 김태임 | - |
dc.identifier.doi | 10.3341/jkos.2012.53.11.1615 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A04265 | - |
dc.contributor.localId | A00831 | - |
dc.contributor.localId | A01080 | - |
dc.contributor.localId | A01870 | - |
dc.contributor.localId | A02263 | - |
dc.contributor.localId | A03303 | - |
dc.contributor.localId | A03631 | - |
dc.contributor.localId | A04329 | - |
dc.relation.journalcode | J01838 | - |
dc.identifier.eissn | 2092-9374 | - |
dc.identifier.pmid | Aspheric intraocular lens ; Pupil size ; Spherical aberration | - |
dc.subject.keyword | Aspheric intraocular lens | - |
dc.subject.keyword | Pupil size | - |
dc.subject.keyword | Spherical aberration | - |
dc.contributor.alternativeName | Kim, Eung Kweon | - |
dc.contributor.alternativeName | Kim, Tae Im | - |
dc.contributor.alternativeName | Seo, Kyuong Yul | - |
dc.contributor.alternativeName | Ahn, Ji Min | - |
dc.contributor.alternativeName | Lee, Hyung Keun | - |
dc.contributor.alternativeName | Jung, Se Hwan | - |
dc.contributor.alternativeName | Han, Kyung Eun | - |
dc.contributor.alternativeName | Han, Jin U | - |
dc.contributor.affiliatedAuthor | Han, Kyung Eun | - |
dc.contributor.affiliatedAuthor | Kim, Eung Kweon | - |
dc.contributor.affiliatedAuthor | Kim, Tae Im | - |
dc.contributor.affiliatedAuthor | Seo, Kyuong Yul | - |
dc.contributor.affiliatedAuthor | Ahn, Ji Min | - |
dc.contributor.affiliatedAuthor | Lee, Hyung Keun | - |
dc.contributor.affiliatedAuthor | Jung, Se Hwan | - |
dc.contributor.affiliatedAuthor | Han, Jin U | - |
dc.citation.volume | 53 | - |
dc.citation.number | 11 | - |
dc.citation.startPage | 1615 | - |
dc.citation.endPage | 1620 | - |
dc.identifier.bibliographicCitation | JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, Vol.53(11) : 1615-1620, 2012 | - |
dc.identifier.rimsid | 29388 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.