2948 994

Cited 0 times in

두 가지 장비를 이용한 각막 지형도 검사의 비교

DC Field Value Language
dc.contributor.author김응권-
dc.contributor.author김태임-
dc.contributor.author서경률-
dc.contributor.author안지민-
dc.date.accessioned2014-12-19T17:54:34Z-
dc.date.available2014-12-19T17:54:34Z-
dc.date.issued2012-
dc.identifier.issn0378-6471-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/92286-
dc.description.abstractPurpose: To compare the corneal measurements of Sirius and Pentacam in normal cornea and post-corneal refractive surgery patients. Methods: Subjects were tested by Pentacam (OCULUS, Wetzlar, Germany), and Sirius (CSO, Firenze, Italy). Measurements included central corneal thickness, thinnest corneal thickness, anterior chamber depth, anterior chamber volume, iridocorneal angle, corneal volume, pupil size, and curvature of cornea. Results: A total of 88 eyes from 44 patients were included in the present study. When comparing Sirius and Pentacam in the normal cornea, corneal thickness (p = 0.693), thinnest corneal thickness (p = 0.386), anterior chamber depth (p = 0.155), anterior chamber volume (p = 0.650), and pupil diameter (p = 0.124) did not differ significantly. Corneal curvature (p < 0.001), corneal volume (p = 0.023), and iridocorneal angle (p < 0.001) were statistically different. When comparing Sirius and Pentacam in post-corneal refractive surgery patients, corneal thickness (p = 0.056) did not differ significantly. There was a statistical difference in corneal curvature (p < 0.001), thinnest corneal thickness (p = 0.019), anterior chamber depth (p < 0.001), anterior chamber volume (p < 0.001), iridocorneal angle (p < 0.001), corneal volume (p < 0.001), and pupil diameter (p < 0.001). Conclusions: Anterior segment measurements with Pentacam and Sirius showed differences in post-corneal refractive surgery patients.-
dc.description.statementOfResponsibilityopen-
dc.relation.isPartOfJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title두 가지 장비를 이용한 각막 지형도 검사의 비교-
dc.title.alternativeComparison of Corneal Measurement Values between Two Types of Topography-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Ophthalmology (안과학)-
dc.contributor.googleauthor이동민-
dc.contributor.googleauthor안지민-
dc.contributor.googleauthor서경률-
dc.contributor.googleauthor김응권-
dc.contributor.googleauthor김태임-
dc.identifier.doi10.3341/jkos.2012.53.11.1584-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00831-
dc.contributor.localIdA01080-
dc.contributor.localIdA01870-
dc.contributor.localIdA02263-
dc.relation.journalcodeJ01838-
dc.identifier.eissn2092-9374-
dc.identifier.pmidCornea ; Pentacam ; Refractive surgery ; Sirius ; Tomography-
dc.subject.keywordCornea-
dc.subject.keywordPentacam-
dc.subject.keywordRefractive surgery-
dc.subject.keywordSirius-
dc.subject.keywordTomography-
dc.contributor.alternativeNameKim, Eung Kweon-
dc.contributor.alternativeNameKim, Tae Im-
dc.contributor.alternativeNameSeo, Kyuong Yul-
dc.contributor.alternativeNameAhn, Ji Min-
dc.contributor.affiliatedAuthorKim, Eung Kweon-
dc.contributor.affiliatedAuthorKim, Tae Im-
dc.contributor.affiliatedAuthorSeo, Kyuong Yul-
dc.contributor.affiliatedAuthorAhn, Ji Min-
dc.citation.volume53-
dc.citation.number11-
dc.citation.startPage1584-
dc.citation.endPage1590-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, Vol.53(11) : 1584-1590, 2012-
dc.identifier.rimsid29387-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.