317 714

Cited 0 times in

Reliability of RTVue, Visante, and slit-lamp adapted ultrasonic pachymetry for central corneal thickness measurement

DC Field Value Language
dc.contributor.author김응권-
dc.contributor.author김태임-
dc.contributor.author서경률-
dc.contributor.author홍진표-
dc.contributor.author이상엽-
dc.date.accessioned2014-12-19T17:48:41Z-
dc.date.available2014-12-19T17:48:41Z-
dc.date.issued2012-
dc.identifier.issn0513-5796-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/92103-
dc.description.abstractPURPOSE: To evaluate reliability of Fourier-domain optical coherence tomography (OCT) (RTVue), time-domain OCT (Visante), and slit-lamp adapted ultrasonic pachymetry (SL-US) in the measurement of central corneal thickness (CCT). MATERIALS AND METHODS: Thirty healthy volunteers visited our clinic 3 times and fifty eyes were measured by one physician. RTVue and Visante were randomly performed, and then SL-US, in which the ultrasound probe was inserted into the Goldmann tonometry mount, was done. During the second visit, each measurement was repeated 3 times. Measurements on the second visit were averaged, and agreement among the instruments was investigated with Bland-Altman plots. RESULTS: RTVue showed smaller repeatability coefficient than Visante and SL-US (4.7, 8.3, and 7.7 μm, respectively). Intersession reproducibility of RTVue and Visante was worse than their repeatability. CCT of RTVue was estimated to be maximally different by 11.8 μm from CCT of Visante and 8.8 μm from CCT of SL-US. The repeatability coefficient of SL-US was 7.7 μm and its reproducibility was similar to the repeatability. CONCLUSION: CCT measured by RTVue showed good reliability and generally agreed with Visante and SL-US. SL-US was as reliable as triple touching conventional US even with a single touch on the cornea.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.relation.isPartOfYONSEI MEDICAL JOURNAL-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAdult-
dc.subject.MESHCornea/anatomy & histology*-
dc.subject.MESHCornea/diagnostic imaging-
dc.subject.MESHCornea/pathology-
dc.subject.MESHCorneal Topography-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHMale-
dc.subject.MESHReproducibility of Results-
dc.subject.MESHTomography, Optical Coherence/methods*-
dc.subject.MESHUltrasonography-
dc.titleReliability of RTVue, Visante, and slit-lamp adapted ultrasonic pachymetry for central corneal thickness measurement-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Ophthalmology (안과학)-
dc.contributor.googleauthorJin Pyo Hong-
dc.contributor.googleauthorSang Min Nam-
dc.contributor.googleauthorTae-Im Kim-
dc.contributor.googleauthorKyoung Yul Seo-
dc.contributor.googleauthorSang Yeop Lee-
dc.contributor.googleauthorAlessandro Meduri-
dc.contributor.googleauthorEung Kweon Kim-
dc.identifier.doi22477010-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00831-
dc.contributor.localIdA01080-
dc.contributor.localIdA01870-
dc.contributor.localIdA04444-
dc.relation.journalcodeJ02813-
dc.identifier.eissn1976-2437-
dc.identifier.pmid22477010-
dc.subject.keywordOptical coherence tomography-
dc.subject.keywordultrasonic pachymetry-
dc.subject.keywordreliability-
dc.subject.keywordcentral corneal thickness-
dc.contributor.alternativeNameKim, Eung Kweon-
dc.contributor.alternativeNameKim, Tae Im-
dc.contributor.alternativeNameSeo, Kyuong Yul-
dc.contributor.alternativeNameHong, Jin Pyo-
dc.contributor.affiliatedAuthorKim, Eung Kweon-
dc.contributor.affiliatedAuthorKim, Tae Im-
dc.contributor.affiliatedAuthorSeo, Kyuong Yul-
dc.contributor.affiliatedAuthorHong, Jin Pyo-
dc.citation.volume53-
dc.citation.number3-
dc.citation.startPage634-
dc.citation.endPage641-
dc.identifier.bibliographicCitationYONSEI MEDICAL JOURNAL, Vol.53(3) : 634-641, 2012-
dc.identifier.rimsid29617-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.