Cited 20 times in
Gasless transaxillary robot-assisted neck dissection: a preclinical feasibility study in four cadavers
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 고윤우 | - |
dc.contributor.author | 이혜연 | - |
dc.contributor.author | 정웅윤 | - |
dc.contributor.author | 최은창 | - |
dc.contributor.author | 홍현준 | - |
dc.date.accessioned | 2014-12-19T17:47:27Z | - |
dc.date.available | 2014-12-19T17:47:27Z | - |
dc.date.issued | 2012 | - |
dc.identifier.issn | 0513-5796 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/92064 | - |
dc.description.abstract | PURPOSE: We hypothesized that comprehensive neck dissection could be achieved via a gasless transaxillary approach using a robotic system. We intended to evaluate the accessibility of level I, IIB and VA nodes with transaxillary robot-assisted neck dissection of four cadavers. MATERIALS AND METHODS: Transaxillary robotic neck dissection was performed in four cadavers through a 7-cm longitudinal incision at the anterior axilla and a 0.8-cm-sized incision in the chest wall. RESULTS: We successfully performed neck dissection from level II to V in all four cadavers. However, dissection of levels IIB and VA, which lie on the cephalic portion of the spinal accessory nerve, was difficult. Vital structures, including the internal jugular vein, carotid artery, vagus nerve, phrenic nerve, superior thyroid artery and hypoglossal nerve, were successfully identified and preserved. CONCLUSION: Our results demonstrate the feasibility of robot-assisted neck dissection using a transaxillary approach. We suggest that gasless, transaxillary robotic neck dissection is a promising technique for treating nodal metastasis in thyroid cancers or in selected squamous cell carcinomas of the head and neck. However, some modification of the approach might be needed when performing comprehensive neck dissections of all levels of the neck. | - |
dc.description.statementOfResponsibility | open | - |
dc.format | application/pdf | - |
dc.relation.isPartOf | YONSEI MEDICAL JOURNAL | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Cadaver | - |
dc.subject.MESH | Endoscopy/instrumentation | - |
dc.subject.MESH | Endoscopy/methods | - |
dc.subject.MESH | Feasibility Studies | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Head and Neck Neoplasms/surgery* | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Neck/blood supply | - |
dc.subject.MESH | Neck/innervation | - |
dc.subject.MESH | Neck/surgery | - |
dc.subject.MESH | Neck Dissection/instrumentation* | - |
dc.subject.MESH | Neck Dissection/methods* | - |
dc.subject.MESH | Neoplasms, Squamous Cell/surgery* | - |
dc.subject.MESH | Robotics/methods* | - |
dc.subject.MESH | Thyroid Neoplasms/surgery* | - |
dc.title | Gasless transaxillary robot-assisted neck dissection: a preclinical feasibility study in four cadavers | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Surgery (외과학) | - |
dc.contributor.googleauthor | Yoo Seob Shin | - |
dc.contributor.googleauthor | Hyun Jun Hong | - |
dc.contributor.googleauthor | Yoon Woo Koh | - |
dc.contributor.googleauthor | Woong Youn Chung | - |
dc.contributor.googleauthor | Hye Yeon Lee | - |
dc.contributor.googleauthor | Jae Min Hong | - |
dc.contributor.googleauthor | Chi Sang Hwang | - |
dc.contributor.googleauthor | Jae Won Chang | - |
dc.contributor.googleauthor | Eun Chang Choi | - |
dc.identifier.doi | 10.3349/ymj.2012.53.1.193 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A00133 | - |
dc.contributor.localId | A03674 | - |
dc.contributor.localId | A04161 | - |
dc.contributor.localId | A04451 | - |
dc.contributor.localId | A03313 | - |
dc.relation.journalcode | J02813 | - |
dc.identifier.eissn | 1976-2437 | - |
dc.identifier.pmid | 22187252 | - |
dc.subject.keyword | Trans-axillary | - |
dc.subject.keyword | robotic | - |
dc.subject.keyword | neck dissection | - |
dc.subject.keyword | cadaver | - |
dc.subject.keyword | squamous cell carcinoma | - |
dc.subject.keyword | endoscope | - |
dc.contributor.alternativeName | Kho, Yoon Woo | - |
dc.contributor.alternativeName | Lee, Hye Yeon | - |
dc.contributor.alternativeName | Chung, Woung Youn | - |
dc.contributor.alternativeName | Choi, Eun Chang | - |
dc.contributor.alternativeName | Hong, Hyun Jun | - |
dc.contributor.affiliatedAuthor | Kho, Yoon Woo | - |
dc.contributor.affiliatedAuthor | Chung, Woung Youn | - |
dc.contributor.affiliatedAuthor | Choi, Eun Chang | - |
dc.contributor.affiliatedAuthor | Hong, Hyun Jun | - |
dc.contributor.affiliatedAuthor | Lee, Hye Yeon | - |
dc.citation.volume | 53 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 193 | - |
dc.citation.endPage | 197 | - |
dc.identifier.bibliographicCitation | YONSEI MEDICAL JOURNAL, Vol.53(1) : 193-197, 2012 | - |
dc.identifier.rimsid | 29588 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.