Bladeless trocar decreases accidental injuries and incisional hernia; further a closure of fascial defect is considered to be unnecessary if a 12-mm bladeless trocar is used at nonmidline. We present a case of bowel herniation after using 12-mm bladeless trocar in robotic colorectal surgery. A 67-year-old woman had rectal cancer and underwent a robot-assisted low anterior resection. The facial defect after using 12-mm bladeless trocar was closed with the routine procedure. On postoperative day 7, her hernia of the trocar site was diagnosed by an abdominal computed tomography. The herniation was reduced with laparoscopic surgery. In conclusion, a trocar site hernia can occur after using a 12-mm bladeless trocar in robotic surgery.
Full Text
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&CSC=Y&NEWS=N&PAGE=fulltext&AN=00129689-201202000-00028&LSLINK=80&D=ovft
DOI
10.1097/SLE.0b013e3182415320
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Surgery (외과학교실) > 1. Journal Papers
Yonsei Authors
Kang, Jeonghyun(강정현) ORCID logo https://orcid.org/0000-0001-7311-6053
Kim, Nam Kyu(김남규) ORCID logo https://orcid.org/0000-0003-0639-5632
Min, Byung Soh(민병소) ORCID logo https://orcid.org/0000-0003-0180-8565
Lee, Kang Young(이강영)
Hur, Hyuk(허혁) ORCID logo https://orcid.org/0000-0002-9864-7229
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/91909
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links