8 981

Cited 0 times in

Comparison of higher order aberrations after implantable Collamer Lens implantation and wavefront-guided LASEK in high myopia

DC Field Value Language
dc.contributor.author김응권-
dc.contributor.author김태임-
dc.contributor.author서경률-
dc.contributor.author안현석-
dc.date.accessioned2014-12-19T17:15:52Z-
dc.date.available2014-12-19T17:15:52Z-
dc.date.issued2012-
dc.identifier.issn1081-597X-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/91084-
dc.description.abstractPURPOSE: To compare changes in ocular higher order aberrations (HOAs) after Visian Implantable Collamer Lens (ICL, STAAR Surgical Co) implantation and wavefront-guided laser epithelial keratomileusis (WFG-LASEK) to correct high myopia. METHODS: This prospective case series comprised 30 eyes (18 patients) that underwent ICL implantation (ICL group) and 33 eyes (18 patients) that underwent WFG-LASEK (WFG-LASEK group). All eyes had spherical equivalent of -6.00 to -9.00 diopters. Entire ocular, internal optic, and corneal HOAs were measured before surgery and 3 months after surgery using a laser ray tracing aberrometer. Contrast sensitivity testing was performed in 10 eyes from each group at a photopic light level of 85 cd/m(2) and a mesopic level of 3 cd/m(2) 3 months after surgery. RESULTS: In the ICL group, HOAs changed for the entire ocular trefoil-y, spherical aberration, internal optic spherical aberration, and corneal trefoil-y. In the WFG-LASEK group, increased HOAs were observed for total HOAs, entire ocular and corneal spherical aberration, secondary astigmatism, and tetrafoil. The ICL group had lower induced aberration values of entire ocular and corneal HOAs compared with the WFG-LASEK group. No significant differences in contrast sensitivity values between groups at the photopic level were noted; however, contrast sensitivity values were significantly lower for 3 (P=.01) and 6 cycles per degree (P<.001) in the WFG-LASEK group at the mesopic level. At the mesopic level, total HOAs, trefoil-y, spherical aberration, and secondary astigmatism were higher in the WFG-LASEK group. CONCLUSIONS: Implantable Collamer Lens implantation induced fewer ocular and corneal HOAs and resulted in better contrast sensitivity at mesopic levels than WFG-LASEK in eyes with high myopia.-
dc.description.statementOfResponsibilityopen-
dc.relation.isPartOfJOURNAL OF REFRACTIVE SURGERY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAberrometry-
dc.subject.MESHAdult-
dc.subject.MESHAnterior Chamber/surgery-
dc.subject.MESHContrast Sensitivity/physiology-
dc.subject.MESHCorneal Wavefront Aberration/physiopathology*-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHKeratectomy, Subepithelial, Laser-Assisted*-
dc.subject.MESHLasers, Excimer/therapeutic use*-
dc.subject.MESHLens Implantation, Intraocular*-
dc.subject.MESHMale-
dc.subject.MESHMyopia, Degenerative/physiopathology-
dc.subject.MESHMyopia, Degenerative/surgery*-
dc.subject.MESHPhakic Intraocular Lenses*-
dc.subject.MESHProspective Studies-
dc.subject.MESHVisual Acuity/physiology-
dc.subject.MESHYoung Adult-
dc.titleComparison of higher order aberrations after implantable Collamer Lens implantation and wavefront-guided LASEK in high myopia-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Ophthalmology (안과학)-
dc.contributor.googleauthorJoo Youn Shin-
dc.contributor.googleauthorHyunseok Ahn-
dc.contributor.googleauthorKyoung Yul Seo-
dc.contributor.googleauthorEung Kweon Kim-
dc.contributor.googleauthorTae-im Kim-
dc.identifier.doi22074464-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00831-
dc.contributor.localIdA01080-
dc.contributor.localIdA01870-
dc.contributor.localIdA02272-
dc.relation.journalcodeJ01730-
dc.identifier.pmid22074464-
dc.identifier.urlhttp://www.healio.com/ophthalmology/journals/JRS/%7BCB281FBF-642D-466C-BA7C-AF6461231B8D%7D/Comparison-of-Higher-Order-Aberrations-After-Implantable-Collamer-Lens-Implantation-and-Wavefront-guided-LASEK-in-High-Myopia-
dc.subject.keywordAberrometry-
dc.subject.keywordAdult-
dc.subject.keywordAnterior Chamber/surgery-
dc.subject.keywordContrast Sensitivity/physiology-
dc.subject.keywordCorneal Wavefront Aberration/physiopathology*-
dc.subject.keywordFemale-
dc.subject.keywordHumans-
dc.subject.keywordKeratectomy, Subepithelial, Laser-Assisted*-
dc.subject.keywordLasers, Excimer/therapeutic use*-
dc.subject.keywordLens Implantation, Intraocular*-
dc.subject.keywordMale-
dc.subject.keywordMyopia, Degenerative/physiopathology-
dc.subject.keywordMyopia, Degenerative/surgery*-
dc.subject.keywordPhakic Intraocular Lenses*-
dc.subject.keywordProspective Studies-
dc.subject.keywordVisual Acuity/physiology-
dc.subject.keywordYoung Adult-
dc.contributor.alternativeNameKim, Eung Kweon-
dc.contributor.alternativeNameKim, Tae Im-
dc.contributor.alternativeNameSeo, Kyuong Yul-
dc.contributor.alternativeNameAhn, Hyun Seok-
dc.contributor.affiliatedAuthorKim, Eung Kweon-
dc.contributor.affiliatedAuthorKim, Tae Im-
dc.contributor.affiliatedAuthorSeo, Kyuong Yul-
dc.contributor.affiliatedAuthorAhn, Hyun Seok-
dc.citation.volume28-
dc.citation.number2-
dc.citation.startPage106-
dc.citation.endPage111-
dc.identifier.bibliographicCitationJOURNAL OF REFRACTIVE SURGERY, Vol.28(2) : 106-111, 2012-
dc.identifier.rimsid33320-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.