dc.description.abstractPURPOSE: To compare the accuracy rates between ultrasound (US)-guided and blind knee intra-articular injection via the suprapatellar bursa. METHODS: Ninety-nine patients with radiographically confirmed knee osteoarthritis (Kellgren/Lawrence grade 2 or 3) without effusion were included. Fifty patients were assigned to the US-guided injection group and 49 to the blind injection group. After a US-guided or blind injection of hyaluronic acid (HA) and contrast dye through the suprapatellar bursa into the knee joint, a radiographic image was obtained in each case to ascertain whether all injected material had reached the intra-articular space. RESULTS: US-guided HA injection exhibited a significantly greater accuracy (48 of 50 knees, 96.0%) than blind injection (41 of 49 knees, 83.7%). CONCLUSIONS: Intra-articular injections through the suprapatellar bursa under US guidance increased the accuracy of knee joint injections.-
dc.description.statementOfResponsibilityopen-
dc.relation.isPartOfJOURNAL OF CLINICAL ULTRASOUND-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAged-
dc.subject.MESHBursa, Synovial-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHHyaluronic Acid/administration & dosage*-
dc.subject.MESHHyaluronic Acid/therapeutic use-
dc.subject.MESHInjections, Intra-Articular/methods-
dc.subject.MESHKnee Joint/diagnostic imaging*-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHOsteoarthritis, Knee/diagnostic imaging-
dc.subject.MESHOsteoarthritis, Knee/drug therapy*-
dc.subject.MESHProspective Studies-
dc.subject.MESHRadiography-
dc.subject.MESHSingle-Blind Method-
dc.subject.MESHUltrasonography, Interventional*-
dc.subject.MESHViscosupplementation/methods*-
dc.subject.MESHViscosupplements/administration & dosage*-
dc.subject.MESHViscosupplements/therapeutic use-
dc.titleAccuracy of blind versus ultrasound-guided suprapatellar bursal injection-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Rehabilitation Medicine (재활의학)-
dc.contributor.googleauthorYong Bum Park-
dc.contributor.googleauthorWon Ah Choi-
dc.contributor.googleauthorYong-Kyun Kim-
dc.contributor.googleauthorSang Chul Lee-
dc.contributor.googleauthorJi Hae Lee-
dc.identifier.doi22033897-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA04125-
dc.relation.journalcodeJ01342-
dc.identifier.eissn1097-0096-
dc.identifier.pmid22033897-
dc.identifier.urlhttp://onlinelibrary.wiley.com/doi/10.1002/jcu.20890/abstract-
dc.subject.keywordknee-
dc.subject.keywordultrasound-
dc.subject.keywordinjection-
dc.contributor.alternativeNameChoi, Won Ah-
dc.contributor.affiliatedAuthorChoi, Won Ah-
dc.citation.volume40-
dc.citation.number1-
dc.citation.startPage20-
dc.citation.endPage25-
dc.identifier.bibliographicCitationJOURNAL OF CLINICAL ULTRASOUND, Vol.40(1) : 20-25, 2012-
dc.identifier.rimsid33487-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Rehabilitation Medicine (재활의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.