dc.description.abstractPURPOSE: The aims of this pilot study were to introduce implant loading devices designed for animal study and to evaluate the validity of the load transmission ability of the loading devices. MATERIALS AND METHODS: Implant loading devices were specially designed and fabricated with two implant abutments and cast metal bars, and orthodontic expansion screw. In six Beagles, all premolars were extracted and two implants were placed in each side of the mandibles. The loading device was inserted two weeks after the implant placement. According to the loading protocol, the load was applied to the implants with different time and method,simulating early, progressive, and delayed loading. The implants were clinically evaluated and the loading devices were removed and replaced to the master cast, followed by stress-strain analysis. Descriptive statistics of remained strain (µε) was evaluated after repeating three cycles of the loading device activation. Statistic analysis was performed using nonparametric, independent t-test with 5% significance level and Friedman's test was also used for verification. RESULTS: The loading devices were in good action. However, four implants in three Beagles showed loss of osseointegration. In stress-strain analysis, loading devices showed similar amount of increase in the remained strain after applying 1-unit load for three times. CONCLUSION: Specialized design of the implant loading device was introduced. The loading device applied similar amount of loads near the implant after each 1-unit loading. However, the direction of the loads was not parallel to the long axis of the implants as predicted before the study.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.relation.isPartOfJOURNAL OF ADVANCED PROSTHODONTICS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titleDevelopment of implant loading device for animal study about various loading protocol: a pilot study-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Prosthodontics (보철과학)-
dc.contributor.googleauthorJoon-Ho Yoon-
dc.contributor.googleauthorYoung-Bum Park-
dc.contributor.googleauthorYuna Cho-
dc.contributor.googleauthorChang-Sung Kim-
dc.contributor.googleauthorSeong-Ho Choi-
dc.contributor.googleauthorHong-Seok Moon-
dc.contributor.googleauthorKeun-Woo Lee-
dc.contributor.googleauthorJune-Sung Shim-
dc.identifier.doi10.4047/jap.2012.4.4.227-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA01041-
dc.contributor.localIdA01395-
dc.contributor.localIdA01567-
dc.contributor.localIdA02211-
dc.contributor.localIdA02688-
dc.contributor.localIdA04081-
dc.relation.journalcodeJ01223-
dc.identifier.eissn2005-7814-
dc.identifier.pmid23236575-
dc.subject.keywordAnimal experimentation-
dc.subject.keywordDental Implants-
dc.subject.keywordDental stress analysis-
dc.subject.keywordImmediate dental implant loading-
dc.subject.keywordOsseointegration-
dc.contributor.alternativeNameKim, Chang Sung-
dc.contributor.alternativeNameMoon, Hong Seok-
dc.contributor.alternativeNamePark, Young Bum-
dc.contributor.alternativeNameShim, June Sung-
dc.contributor.alternativeNameLee, Keun Woo-
dc.contributor.alternativeNameChoi, Seong Ho-
dc.contributor.affiliatedAuthorKim, Chang Sung-
dc.contributor.affiliatedAuthorMoon, Hong Seok-
dc.contributor.affiliatedAuthorPark, Young Bum-
dc.contributor.affiliatedAuthorShim, June Sung-
dc.contributor.affiliatedAuthorLee, Keun Woo-
dc.contributor.affiliatedAuthorChoi, Seong Ho-
dc.citation.volume4-
dc.citation.number4-
dc.citation.startPage227-
dc.citation.endPage234-
dc.identifier.bibliographicCitationJOURNAL OF ADVANCED PROSTHODONTICS, Vol.4(4) : 227-234, 2012-
dc.identifier.rimsid32865-
dc.type.rimsART-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Periodontics (치주과학교실) > 1. Journal Papers
2. College of Dentistry (치과대학) > Dept. of Prosthodontics (보철과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.