OCT-Verified Peri-Strut Low-Intensity Areas and the Extent of Neointimal Formation After 3 Years Following Stent Implantation

Authors
 Jin-Ho Choi  ;  Juan F. Granada  ;  Jung-Sun Kim  ;  Young Bin Song  ;  Joo-Yong Hahn  ;  Seung Hyuk Choi  ;  Armando Tellez  ;  Krzysztof Milewski  ;  Myeong-Ki Hong  ;  Yangsoo Jang  ;  Sang Hoon Lee  ;  Hyeon-Cheol Gwon 
Citation
 JACC-CARDIOVASCULAR IMAGING, Vol.5(11) : 1156-1160, 2012 
Journal Title
JACC-CARDIOVASCULAR IMAGING
ISSN
 1936-878X 
Issue Date
2012
MeSH
Coronary Restenosis/etiology ; Coronary Restenosis/pathology ; Coronary Vessels/pathology* ; Cross-Sectional Studies ; Drug-Eluting Stents ; Humans ; Metals ; Neointima* ; Percutaneous Coronary Intervention/adverse effects ; Percutaneous Coronary Intervention/instrumentation* ; Predictive Value of Tests ; Prosthesis Design ; Stents* ; Time Factors ; Tomography, Optical Coherence* ; Treatment Outcome
Keywords
optical coherence tomography ; peri-strut low intensity ; stent