dc.description.abstractRecently, as we move toward a society with an increasingly aged population, wearable U-health devices in various shapes with smart wear have been developed in order to conveniently measure health variables without using hands in daily life or at home. However, the problem is that only supply of the wearable U-health devices is focused and its applicable devices are studied and developed, which has resulted in lack of awareness of importance of performance evaluation. In this study, two electrodes were fabricated using conductive fabric which can be used as electrode if attached to wearable U-health devices or smart wear in order to measure ECG signal. Two electrodes those were fabricated using conductive fabric were compared the correlation, impedance and CMRR with patch typed Ag-AgCl electrode-normally used for measurement of ECG signal, so that the study would find out if the fabricated electrode can be used with the wearable U-health devices by testing and evaluating performances.-
dc.description.statementOfResponsibilityopen-
dc.relation.isPartOfJournal of the Institute of Electronics and Information Engineers of Korea (전자공학회논문지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title전도성 섬유 기반 심전도 전극의 성능 평가에 관한 연구-
dc.title.alternativeA study on performance evaluation for Electrocardiography signal measurement electrode based on conductive fabric-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Medical Engineering (의학공학)-
dc.contributor.googleauthor강보규-
dc.contributor.googleauthor유선국-
dc.identifier.doi10.5573/ieek.2013.50.2.210-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA02471-
dc.relation.journalcodeJ01784-
dc.identifier.pmidConductive Fabric ; Performance Evaluation ; Impedance ; Correlation ; Electrode-
dc.identifier.urlhttp://dx.doi.org/10.5573/ieek.2013.50.2.210-
dc.subject.keywordConductive Fabric-
dc.subject.keywordPerformance Evaluation-
dc.subject.keywordImpedance-
dc.subject.keywordCorrelation-
dc.subject.keywordElectrode-
dc.contributor.alternativeNameYoo, Sun Kook-
dc.contributor.affiliatedAuthorYoo, Sun Kook-
dc.rights.accessRightsfree-
dc.citation.volume50-
dc.citation.number2-
dc.citation.startPage210-
dc.citation.endPage220-
dc.identifier.bibliographicCitationJournal of the Institute of Electronics and Information Engineers of Korea (전자공학회논문지), Vol.50(2) : 210-220, 2013-
dc.identifier.rimsid33104-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Medical Engineering (의학공학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.