435 592

Cited 0 times in

전안부 빛간섭단층촬영기를 이용한 백내장 절개창의 크기에 따른 창상치유과정의 형태학적 관찰

DC Field Value Language
dc.contributor.author김응권-
dc.contributor.author김태임-
dc.contributor.author이형근-
dc.date.accessioned2014-12-18T09:18:49Z-
dc.date.available2014-12-18T09:18:49Z-
dc.date.issued2013-
dc.identifier.issn0378-6471-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/87937-
dc.description.abstractPurpose To investigate wound characteristics and ultrastructural changes in the 2.2-mm and 2.8-mm main corneal incisions. Methods Forty-four eyes of 34 patients undergoing cataract surgery were randomized to receive a 2.2-mm or 2.8-mm main corneal incision. All incisions were evaluated 1, 7, and 30 days postoperatively using anterior segment optical coherence tomography. The angle, length, maximal thickness of the incision, and if present, corneal gap length and incision gap area were calculated. The existence of Descemet's membrane detachment was recorded. Results The mean endothelial gap length and gap area of the 2.2-mm wound were larger than the 2.8-mm, with the only statistically significant difference observed on postoperative day 30 (p = 0.015 and 0.027, respectively). There was no difference in the mean incision angle, length, and corneal thickness between the 2 incision sizes. The ratio of Descemet's membrane detachment increased with older age and low postoperative IOP, but not associated with incision size (p < 0.05). Conclusions Both the 2.2-mm and 2.8-mm main corneal incisions showed excellent wound healing outcome without significant postoperative complications. Older patients with low postoperative IOP required a more careful wound care management. The incision parameters in the present study can be used as an indicator of the healing process to reduce wound-related complications.-
dc.description.statementOfResponsibilityopen-
dc.relation.isPartOfJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title전안부 빛간섭단층촬영기를 이용한 백내장 절개창의 크기에 따른 창상치유과정의 형태학적 관찰-
dc.title.alternativeThe Morphological Changes in Main Corneal Incision (2.2 mm vs. 2.8 mm) Evaluated Using Anterior Segment Optical Coherence Tomography-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Ophthalmology (안과학)-
dc.contributor.googleauthor김진형-
dc.contributor.googleauthor김태임-
dc.contributor.googleauthor김응권-
dc.contributor.googleauthor이형근-
dc.identifier.doi10.3341/jkos.2013.54.6.877-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00831-
dc.contributor.localIdA01080-
dc.contributor.localIdA03303-
dc.relation.journalcodeJ01838-
dc.identifier.eissn2092-9374-
dc.identifier.pmidAnterior segment optical coherence tomography ; Main corneal incision ; Morphology ; Phacoemulsification-
dc.subject.keywordAnterior segment optical coherence tomography-
dc.subject.keywordMain corneal incision-
dc.subject.keywordMorphology-
dc.subject.keywordPhacoemulsification-
dc.contributor.alternativeNameKim, Eung Kweon-
dc.contributor.alternativeNameKim, Tae Im-
dc.contributor.alternativeNameLee, Hyung Keun-
dc.contributor.affiliatedAuthorKim, Eung Kweon-
dc.contributor.affiliatedAuthorKim, Tae Im-
dc.contributor.affiliatedAuthorLee, Hyung Keun-
dc.rights.accessRightsfree-
dc.citation.volume54-
dc.citation.number6-
dc.citation.startPage877-
dc.citation.endPage886-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, Vol.54(6) : 877-886, 2013-
dc.identifier.rimsid33860-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.