304 569

Cited 11 times in

Comparison of Preoperative and Postoperative Ocular Biometry in Eyes with Phakic Intraocular Lens Implantations

DC Field Value Language
dc.contributor.author김응권-
dc.contributor.author김태임-
dc.contributor.author서경률-
dc.contributor.author신주연-
dc.date.accessioned2014-12-18T09:01:43Z-
dc.date.available2014-12-18T09:01:43Z-
dc.date.issued2013-
dc.identifier.issn0513-5796-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/87396-
dc.description.abstractPURPOSE: To compare preoperative and postoperative ocular biometry in patients with iris-fixated phakic intraocular lens (pIOLs): Artisan and Artiflex. MATERIALS AND METHODS: This study included 40 eyes with Artisan and 36 eyes with Artiflex pIOL implants. Anterior chamber depth (ACD) and axial length (AL) were measured by applanation ultrasonography (A-scan) and partial coherence interferometry (IOLMaster) preoperatively and 3 months after pIOL implantation. RESULTS: ACD measurements after Artisan or Artiflex pIOL implantation were smaller than preoperative measurements. Specifically, the difference after Artisan pIOL implantation was -1.07 ± 0.17 mm by A-scan and -0.08 ± 0.08 mm by IOLMaster. The difference after Artiflex pIOL implantation was -1.31 ± 0.15 mm by A-scan and -0.05 ± 0.07 mm by IOLMaster. After Artisan pIOL implantation, differences in AL measurements by A-scan were insignificant (difference: -0.03 ± 0.15 mm), whereas postoperative AL measurements by IOLMaster were significantly longer than preoperative measurements (difference: 0.12 ± 0.07 mm). After Artiflex pIOL implantation, AL measurements by both A-scan and IOLMaster were significantly longer than preoperative measurements (difference: 0.09 ± 0.16 mm by A-scan and 0.07 ± 0.10 mm by IOLMaster). In the Artiflex group, differences in AL measurements by A-scan correlated with the central thickness of the Artiflex pIOL. CONCLUSION: ACD and AL measurements were influenced by iris-fixated phakic IOL implantation.-
dc.description.statementOfResponsibilityopen-
dc.relation.isPartOfYONSEI MEDICAL JOURNAL-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAdult-
dc.subject.MESHBiometry-
dc.subject.MESHEye/diagnostic imaging-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHInterferometry-
dc.subject.MESHLens Implantation, Intraocular/adverse effects*-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHPostoperative Complications-
dc.subject.MESHUltrasonography-
dc.titleComparison of Preoperative and Postoperative Ocular Biometry in Eyes with Phakic Intraocular Lens Implantations-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Ophthalmology (안과학)-
dc.contributor.googleauthorJoo Youn Shin-
dc.contributor.googleauthorJae Bum Lee-
dc.contributor.googleauthorKyoung Yul Seo-
dc.contributor.googleauthorEung Kweon Kim-
dc.contributor.googleauthorTae-im Kim-
dc.identifier.doi10.3349/ymj.2013.54.5.1259-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00831-
dc.contributor.localIdA01080-
dc.contributor.localIdA01870-
dc.contributor.localIdA02154-
dc.relation.journalcodeJ02813-
dc.identifier.eissn1976-2437-
dc.identifier.pmid23918579-
dc.subject.keywordBiometry-
dc.subject.keywordanterior chamber depth-
dc.subject.keywordaxial length-
dc.subject.keywordphakic intraocular lenses-
dc.contributor.alternativeNameKim, Eung Kweon-
dc.contributor.alternativeNameKim, Tae Im-
dc.contributor.alternativeNameSeo, Kyuong Yul-
dc.contributor.alternativeNameShin, Joo Youn-
dc.contributor.affiliatedAuthorKim, Eung Kweon-
dc.contributor.affiliatedAuthorKim, Tae Im-
dc.contributor.affiliatedAuthorSeo, Kyuong Yul-
dc.contributor.affiliatedAuthorShin, Joo Youn-
dc.rights.accessRightsfree-
dc.citation.volume54-
dc.citation.number5-
dc.citation.startPage1259-
dc.citation.endPage1265-
dc.identifier.bibliographicCitationYONSEI MEDICAL JOURNAL, Vol.54(5) : 1259-1265, 2013-
dc.identifier.rimsid33028-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.