Cited 0 times in 
Cited 0 times in 
Non-invasive Reduction of Accessory Breast Fat Using Multilayer High-Intensity Focused Ultrasound: A Quantitative Ultrasound-Based Study
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Yi, Kyu-Ho | - |
| dc.contributor.author | Park, Yerin | - |
| dc.contributor.author | Sydorchuk, Olena | - |
| dc.contributor.author | Cartier, Hugues | - |
| dc.contributor.author | Garson, Sebastien | - |
| dc.contributor.author | Ascher, Benjamin | - |
| dc.contributor.author | 이규호 | - |
| dc.date.accessioned | 2026-06-10T05:55:40Z | - |
| dc.date.available | 2026-06-10T05:55:40Z | - |
| dc.date.created | 2026-06-01 | - |
| dc.date.issued | 2026-05 | - |
| dc.identifier.issn | 0278-4297 | - |
| dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/212499 | - |
| dc.description.abstract | Objectives Accessory breast tissue often presents as localized axillary subcutaneous fullness, presenting as a palpable soft-tissue bulge composed of adipose or glandular elements, causing mechanical discomfort and esthetic concern. While surgical excision remains effective, it ma result in scarring, postoperative pain, and risks of seroma/hematoma or contour irregularity, leading to growing interest in noninvasive approaches. The objective of the study is to investigate the effect of noninvasive high-intensity focused ultrasound (HIFU) on subcutaneous fat thickness in axillary accessory breast tissue.Methods This prospective study enrolled 30 women with BMI >= 27 kg/m2 and accessory breast fat. All participants underwent a single HIFU session using multiple focal depths of 4.5, 6.0, and 9.0 mm at operating frequencies of 4 and 2 MHz, with energy settings of 1.5-2.0 J per shot. Fat thickness was measured by ultrasound at baseline and 8 weeks. Secondary outcomes included investigator-rated Global Aesthetic Improvement Scale (GAIS) and patient satisfaction scores.Results Among the 28 participants who completed the 8-week follow-up, mean subcutaneous fat thickness decreased from 19.2 +/- 3.4 mm at baseline to 15.8 +/- 3.1 mm at 8 weeks. The mean paired reduction was 3.4 +/- 1.6 mm (17.7%), which was statistically significant (95% CI, 2.8-4.0 mm; p = 1.1 & times; 10(-)& sup1;& sup1;). All participants showed GAIS improvement with high satisfaction. No serious adverse events were observed; mild and transient effects included transient thermal discomfort and localized erythema resolving within several hours to 2 days, and no cases of skin burn were identified.Conclusion Non-invasive HIFU produced a measurable reduction of accessory breast fat with favorable esthetic outcomes and an acceptable safety profile. | - |
| dc.language | English | - |
| dc.publisher | American Institute of Ultrasound in Medicine | - |
| dc.relation.isPartOf | JOURNAL OF ULTRASOUND IN MEDICINE | - |
| dc.relation.isPartOf | JOURNAL OF ULTRASOUND IN MEDICINE | - |
| dc.title | Non-invasive Reduction of Accessory Breast Fat Using Multilayer High-Intensity Focused Ultrasound: A Quantitative Ultrasound-Based Study | - |
| dc.type | Article | - |
| dc.contributor.googleauthor | Yi, Kyu-Ho | - |
| dc.contributor.googleauthor | Park, Yerin | - |
| dc.contributor.googleauthor | Sydorchuk, Olena | - |
| dc.contributor.googleauthor | Cartier, Hugues | - |
| dc.contributor.googleauthor | Garson, Sebastien | - |
| dc.contributor.googleauthor | Ascher, Benjamin | - |
| dc.identifier.doi | 10.1002/jum.70238 | - |
| dc.relation.journalcode | J01920 | - |
| dc.identifier.eissn | 1550-9613 | - |
| dc.identifier.pmid | 42104539 | - |
| dc.identifier.url | https://onlinelibrary.wiley.com/doi/10.1002/jum.70238 | - |
| dc.subject.keyword | accessory breast tissue | - |
| dc.subject.keyword | high-intensity focused ultrasound | - |
| dc.subject.keyword | noninvasive fat reduction | - |
| dc.subject.keyword | subcutaneous fat thickness | - |
| dc.subject.keyword | ultrasound assessment | - |
| dc.contributor.affiliatedAuthor | Yi, Kyu-Ho | - |
| dc.identifier.scopusid | 2-s2.0-105038366220 | - |
| dc.identifier.wosid | 001759495800001 | - |
| dc.identifier.bibliographicCitation | JOURNAL OF ULTRASOUND IN MEDICINE, 2026-05 | - |
| dc.identifier.rimsid | 93052 | - |
| dc.type.rims | ART | - |
| dc.description.journalClass | 1 | - |
| dc.description.journalClass | 1 | - |
| dc.subject.keywordAuthor | accessory breast tissue | - |
| dc.subject.keywordAuthor | high-intensity focused ultrasound | - |
| dc.subject.keywordAuthor | noninvasive fat reduction | - |
| dc.subject.keywordAuthor | subcutaneous fat thickness | - |
| dc.subject.keywordAuthor | ultrasound assessment | - |
| dc.subject.keywordPlus | SUBCUTANEOUS FAT | - |
| dc.subject.keywordPlus | DEVICE | - |
| dc.subject.keywordPlus | SAFETY | - |
| dc.subject.keywordPlus | RADIOFREQUENCY | - |
| dc.subject.keywordPlus | CRYOLIPOLYSIS | - |
| dc.subject.keywordPlus | EFFICACY | - |
| dc.subject.keywordPlus | EVALUATE | - |
| dc.type.docType | Article; Early Access | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalWebOfScienceCategory | Acoustics | - |
| dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.relation.journalResearchArea | Acoustics | - |
| dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.