0 36

Cited 0 times in

Cited 0 times in

Non-invasive Reduction of Accessory Breast Fat Using Multilayer High-Intensity Focused Ultrasound: A Quantitative Ultrasound-Based Study

DC Field Value Language
dc.contributor.authorYi, Kyu-Ho-
dc.contributor.authorPark, Yerin-
dc.contributor.authorSydorchuk, Olena-
dc.contributor.authorCartier, Hugues-
dc.contributor.authorGarson, Sebastien-
dc.contributor.authorAscher, Benjamin-
dc.contributor.author이규호-
dc.date.accessioned2026-06-10T05:55:40Z-
dc.date.available2026-06-10T05:55:40Z-
dc.date.created2026-06-01-
dc.date.issued2026-05-
dc.identifier.issn0278-4297-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/212499-
dc.description.abstractObjectives Accessory breast tissue often presents as localized axillary subcutaneous fullness, presenting as a palpable soft-tissue bulge composed of adipose or glandular elements, causing mechanical discomfort and esthetic concern. While surgical excision remains effective, it ma result in scarring, postoperative pain, and risks of seroma/hematoma or contour irregularity, leading to growing interest in noninvasive approaches. The objective of the study is to investigate the effect of noninvasive high-intensity focused ultrasound (HIFU) on subcutaneous fat thickness in axillary accessory breast tissue.Methods This prospective study enrolled 30 women with BMI >= 27 kg/m2 and accessory breast fat. All participants underwent a single HIFU session using multiple focal depths of 4.5, 6.0, and 9.0 mm at operating frequencies of 4 and 2 MHz, with energy settings of 1.5-2.0 J per shot. Fat thickness was measured by ultrasound at baseline and 8 weeks. Secondary outcomes included investigator-rated Global Aesthetic Improvement Scale (GAIS) and patient satisfaction scores.Results Among the 28 participants who completed the 8-week follow-up, mean subcutaneous fat thickness decreased from 19.2 +/- 3.4 mm at baseline to 15.8 +/- 3.1 mm at 8 weeks. The mean paired reduction was 3.4 +/- 1.6 mm (17.7%), which was statistically significant (95% CI, 2.8-4.0 mm; p = 1.1 & times; 10(-)& sup1;& sup1;). All participants showed GAIS improvement with high satisfaction. No serious adverse events were observed; mild and transient effects included transient thermal discomfort and localized erythema resolving within several hours to 2 days, and no cases of skin burn were identified.Conclusion Non-invasive HIFU produced a measurable reduction of accessory breast fat with favorable esthetic outcomes and an acceptable safety profile.-
dc.languageEnglish-
dc.publisherAmerican Institute of Ultrasound in Medicine-
dc.relation.isPartOfJOURNAL OF ULTRASOUND IN MEDICINE-
dc.relation.isPartOfJOURNAL OF ULTRASOUND IN MEDICINE-
dc.titleNon-invasive Reduction of Accessory Breast Fat Using Multilayer High-Intensity Focused Ultrasound: A Quantitative Ultrasound-Based Study-
dc.typeArticle-
dc.contributor.googleauthorYi, Kyu-Ho-
dc.contributor.googleauthorPark, Yerin-
dc.contributor.googleauthorSydorchuk, Olena-
dc.contributor.googleauthorCartier, Hugues-
dc.contributor.googleauthorGarson, Sebastien-
dc.contributor.googleauthorAscher, Benjamin-
dc.identifier.doi10.1002/jum.70238-
dc.relation.journalcodeJ01920-
dc.identifier.eissn1550-9613-
dc.identifier.pmid42104539-
dc.identifier.urlhttps://onlinelibrary.wiley.com/doi/10.1002/jum.70238-
dc.subject.keywordaccessory breast tissue-
dc.subject.keywordhigh-intensity focused ultrasound-
dc.subject.keywordnoninvasive fat reduction-
dc.subject.keywordsubcutaneous fat thickness-
dc.subject.keywordultrasound assessment-
dc.contributor.affiliatedAuthorYi, Kyu-Ho-
dc.identifier.scopusid2-s2.0-105038366220-
dc.identifier.wosid001759495800001-
dc.identifier.bibliographicCitationJOURNAL OF ULTRASOUND IN MEDICINE, 2026-05-
dc.identifier.rimsid93052-
dc.type.rimsART-
dc.description.journalClass1-
dc.description.journalClass1-
dc.subject.keywordAuthoraccessory breast tissue-
dc.subject.keywordAuthorhigh-intensity focused ultrasound-
dc.subject.keywordAuthornoninvasive fat reduction-
dc.subject.keywordAuthorsubcutaneous fat thickness-
dc.subject.keywordAuthorultrasound assessment-
dc.subject.keywordPlusSUBCUTANEOUS FAT-
dc.subject.keywordPlusDEVICE-
dc.subject.keywordPlusSAFETY-
dc.subject.keywordPlusRADIOFREQUENCY-
dc.subject.keywordPlusCRYOLIPOLYSIS-
dc.subject.keywordPlusEFFICACY-
dc.subject.keywordPlusEVALUATE-
dc.type.docTypeArticle; Early Access-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalWebOfScienceCategoryAcoustics-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalResearchAreaAcoustics-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Oral Biology (구강생물학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.