22 29

Cited 0 times in

Cited 0 times in

Thread Depth Effects on Stability and Positional Accuracy in Guided Immediate Implants: A Randomized Controlled Trial

Authors
 Kwon, Na-Yoon  ;  Jung, Ji-Young  ;  Ko, Kyung-A  ;  Park, Seung-Hyun  ;  Strauss, Franz Josef  ;  Lee, Jung-Seok 
Citation
 CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, Vol.28(2), 2026-04 
Article Number
 e70145 
Journal Title
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH
ISSN
 1523-0899 
Issue Date
2026-04
MeSH
Adult ; Aged ; Dental Implantation, Endosseous* / methods ; Dental Implants* ; Dental Prosthesis Design* ; Female ; Humans ; Immediate Dental Implant Loading* / methods ; Male ; Middle Aged ; Surgery, Computer-Assisted* / methods ; Torque
Keywords
immediate implant ; implant stability ; macro-design ; marginal bone level ; positional accuracy ; thread depth
Abstract
Objectives To evaluate the influence of implant thread depth on implant stability and positional accuracy in fully guided immediate implant placement.Materials and Methods Fifty-four patients received a reference tapered (BLT), a standard-thread (MST), or a deep-thread implant (MDT). Fifty-four implants were placed using fully guided surgery and evaluated over 1-year follow-up. Primary outcomes were implant stability (insertion torque, ISQ, ISV). Secondary outcomes included positional accuracy and marginal bone level (MBL) at 12 months.Results Primary and longitudinal stability were comparable across groups. Insertion torque was highest for MDT implants, followed by MST and BLT implants (BLT: 35.28 +/- 11.18; MST: 40.00 +/- 11.88; MDT: 43.89 +/- 10.92 Ncm; p = 0.062). A higher proportion of MDT implants achieved insertion torque >= 40 Ncm (MDT: 14/18; MST: 12/18; BLT: 8/18). Angular deviation differed among implant groups (MDT: 5.57 degrees +/- 3.71 degrees; BLT: 4.73 degrees +/- 2.46 degrees; MST: 3.58 degrees +/- 1.81 degrees; p = 0.062). In subgroup analysis comparing implants differing only in thread depth (MST vs. MDT), angular deviation was significantly greater for MDT (p = 0.029), particularly in molar sites. At 12 months, MBL did not differ significantly among groups.Conclusions In fully guided immediate implant placement, deeper-thread implants showed higher insertion torque values but were associated with greater angular deviation, while longitudinal stability and marginal bone levels remained comparable. Deeper-thread designs may be beneficial when enhanced primary stability is required, provided careful angulation control is ensured.Trial Registration cris.nih.go.kr Identifier: KCT0009402; This clinical trial was not registered prior to participant recruitment and randomization
Files in This Item:
92764.pdf Download
DOI
10.1111/cid.70145
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Periodontics (치주과학교실) > 1. Journal Papers
Yonsei Authors
Ko, Kyung-A(고경아)
Park, Seung-Hyun(박승현)
Lee, Jung Seok(이중석) ORCID logo https://orcid.org/0000-0003-1276-5978
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/212238