Stability of commonly used antibiotics solutions in the accufuser® elastometric infusion device under recommended storage and used conditions

DC Field Value Language
dc.contributor.authorLee, Ga-Young-
dc.contributor.authorKim, Min-Jeong-
dc.contributor.authorKang, Mina-
dc.contributor.authorPark, Yoo-Sin-
dc.contributor.authorKim, Shin-Hee-
dc.contributor.authorKim, Sang-Yeon-
dc.contributor.authorKang, Ju-Seop-
dc.date.accessioned2026-05-14T02:47:47Z-
dc.date.available2026-05-14T02:47:47Z-
dc.date.created2026-05-13-
dc.date.issued2011-05-
dc.identifier.issn1876-3960-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/212190-
dc.description.abstractObjectives: The stability of two kinds of solution of penicillin G potassium [PEN-K, 10K U/mL in 5% dextrose water, D5W and 50K U/mL in 0.9% sodium chloride in water, NS) into the intravenous infusion device, Accufuser®, storage were evaluated at controlled temperature (CT, 4±2°C and RT, 25±2°C) during 6 weeks. Methods: Studies were performed using both NS (PEN-K 50K U/mL) and D5W (PEN-K 10K U/mL) injectable solutions. The resulting solutions were transferred to Accufuser® infusion device for storage at CT or RT. Effects of period of storage (from 0 to 6 weeks) and temperature (CT and RT) on the physical appearance and concentrations of PEN-K were determined by visual clarity, pH and antibiotic concentrations by measurement with stability-indicating high-performance liquid chromatography (HPLC) method. Results: In NS (50 K U/mL) and D5W (10K U/mL) solutions, concentrations of PEN-K were slightly change and remained 94.18 and 83.42% at CT after 1 week, respectively. Otherwise, these were rapidly decreased with time and reached to 74.65 and 75.59% in NS (50K U/mL) and D5W (10K U/mL) solutions at RT after 48 h, respectively. Moderate decrement of pH was observed in cold storage and it was shown no significant changes at 6 weeks in the RT conditions. In CT, no significant changes in physical appearance or color of the solutions were observed during the study. Conclusion: Two kinds of PEN-K D5W(10K U/mL) and NS(50K U/mL) solution were shown different chemical stability with time in Accufuser® infusion device without any significant physical change and retained about 70% of initial concentration after 48 h in RT and 80 % after 2 weeks in CT, respectively. We suggested that PEN-K solutions of 50K U/mL NS and 10K U/mL D5W in an Accufuser® infusion device should be preferentially applicable only in CT for 48 h in clinical situations. © Lee et al.; Licensee Bentham Open.-
dc.language영어-
dc.relation.isPartOfOpen Nutraceuticals Journal-
dc.titleStability of commonly used antibiotics solutions in the accufuser® elastometric infusion device under recommended storage and used conditions-
dc.typeArticle-
dc.contributor.googleauthorLee, Ga-Young-
dc.contributor.googleauthorKim, Min-Jeong-
dc.contributor.googleauthorKang, Mina-
dc.contributor.googleauthorPark, Yoo-Sin-
dc.contributor.googleauthorKim, Shin-Hee-
dc.contributor.googleauthorKim, Sang-Yeon-
dc.contributor.googleauthorKang, Ju-Seop-
dc.identifier.doi10.2174/1876396001104010125-
dc.subject.keywordAccufuser®-
dc.subject.keywordInfusion device-
dc.subject.keywordPenicillin G potassium-
dc.subject.keywordStability-
dc.contributor.affiliatedAuthorKang, Mina-
dc.identifier.scopusid2-s2.0-79958106983-
dc.citation.volume4-
dc.citation.startPage125-
dc.citation.endPage129-
dc.identifier.bibliographicCitationOpen Nutraceuticals Journal, Vol.4 : 125-129, 2011-05-
dc.identifier.rimsid92889-
dc.type.rimsART-
dc.description.journalClass1-
dc.description.journalClass1-
dc.subject.keywordAuthorAccufuser®-
dc.subject.keywordAuthorInfusion device-
dc.subject.keywordAuthorPenicillin G potassium-
dc.subject.keywordAuthorStability-