Effect of scan body geometric configuration and library design on digital implant impression accuracy

Authors
 Moon, Hong Seok  ;  Choi, Ahreum  ;  Oh, Kyung Chul  ;  Sun, Minji  ;  Kim, Jaeyoung 
Citation
 JOURNAL OF ADVANCED PROSTHODONTICS, Vol.18(1) : 55-66, 2026-02 
Journal Title
JOURNAL OF ADVANCED PROSTHODONTICS
ISSN
 2005-7806 
Issue Date
2026-02
Keywords
Intraoral scan ; Scan body ; Flat indexing surface ; Short scan body ; Accuracy
Abstract
PURPOSE. The purpose of this in vitro study was to evaluate how variations in scan body geometry, specifically body height and the length of the flat indexing surface (FIS), affect linear and angular accuracy when combined with truncated or full-geometry library files. MATERIALS AND METHODS. Nine scan body geometries were fabricated by combining three body heights (4, 5, and 6 mm) with three FIS lengths (1, 2, and 3 mm). Digital impressions were superimposed onto truncated or full-geometry library files. Linear deviation (Delta D) and angular deviation (Delta A) were calculated by comparing aligned scan bodies with coordinate measuring machine references. Linear and angular deviations were compared between library types using the Mann-Whitney U test, and differences among body heights and FIS lengths were evaluated using the Kruskal-Wallis test with Dunn's post-hoc test (alpha = .05).RESULTS. Linear deviation remained within a comparable range, and most geometry-library comparisons did not show a significant difference from body height, FIS length, or library morphology (P > .05). Angular deviation demonstrated geometry-dependent behavior, increasing only in the 4-mm body paired with larger FIS lengths, particularly when full-geometry libraries were used. No significant angular differences were observed in the 5-mm or 6-mm body groups. CONCLUSION Digital implant registration remained stable across most configurations. Shortened scan bodies performed reliably when FIS dimensions were preserved. Angular accuracy was more sensitive to geometry-library interactions, with truncated libraries improving stability.
Files in This Item:
92110.pdf Download
DOI
10.4047/jap.2026.18.1.55
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Prosthodontics (보철과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Jae-Young(김재영)
Moon, Hong Seok(문홍석) ORCID logo https://orcid.org/0000-0001-8118-8145
Oh, Kyung Chul(오경철) ORCID logo https://orcid.org/0000-0003-4584-2597
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/211562
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links