21 31

Cited 0 times in

Cited 0 times in

Intraoperative Visual Evoked Potential Monitoring in Endoscopic Endonasal Surgery for Nonpituitary Adenoma Suprasellar Tumors

Authors
 Kwon, Young Nam  ;  Lee, Hwa Reung  ;  Lee, Myung Jae  ;  Kim, Young Ung  ;  Kim, Seung Woo  ;  Shin, Ha Young  ;  Kim, Sung-Min  ;  Moon, Ju Hyung  ;  Chang, Jong Hee  ;  Kim, Eui Hyun 
Citation
 JOURNAL OF CLINICAL NEUROLOGY, Vol.22(2) : 221-228, 2026-03 
Journal Title
JOURNAL OF CLINICAL NEUROLOGY
ISSN
 1738-6586 
Issue Date
2026-03
Keywords
intraoperative neurophysiological monitoring ; visual evoked potential ; suprasellar tumor ; endoscopic endonasal surgery ; optic nerve
Abstract
Background and Purpose Intraoperative visual evoked potential (VEP) monitoring has been studied mainly in pituitary adenoma, while its role in nonpituitary suprasellar tumors has remained unclear. This study evaluated the predictive usefulness of intraoperative VEP monitoring during endoscopic endonasal surgery (EES) and aimed to identify optimal alarm criteria for visual outcomes. Methods We retrospectively analyzed a cohort of 87 patients who underwent EES with intraoperative VEP monitoring between April 2021 and September 2023. Visual outcomes were evaluated preoperatively and at short-term (<= 3 months) and long-term (12 months) followups, with visual deterioration at these time points defined as worsening of either visual acuity or the visual field. Reductions in the VEP amplitude were quantified using both the maximum intraoperative decrease and the final amplitude after recovery. Receiver operating characteristic (ROC) curve analyses were performed to identify the optimal alarm thresholds, and the sensitivity, specificity, positive predictive value, and negative predictive value were calculated for short-term and long-term visual deteriorations. Results Short-term and long-term visual deteriorations were detected in 12 (9.2%) and 5 (3.8%) of the 130 analyzed eyes, respectively. ROC curve analyses identified >= 40% and >= 30% reductions in the N75-P100 amplitude as optimal alarm criteria for short-term and long-term visual deteriorations, respectively. A 30% reduction without intraoperative recovery demonstrated markedly higher sensitivity than the conventional 50% alarm threshold for short-term (58.3% vs. 33.3%) and long-term (80.0% vs. 20.0%) outcomes, while maintaining acceptable specificity (82.2% and 80.8%, respectively). Conclusions A 30% reduction in amplitude represents a more-sensitive and clinically relevant alarm threshold than a 50% reduction for intraoperative VEP monitoring during EES for nonpituitary suprasellar tumors. Incorporating both the magnitude and recovery pattern of VEP amplitude changes may improve the accuracy of predictions of long-term visual deterioration. However, the potential for false positives warrants cautious interpretation, and further studies are needed to validate the impact of intraoperative VEP monitoring on visual outcomes.
Files in This Item:
92031.pdf Download
DOI
10.3988/jcn.2025.0207
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Neurology (신경과학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Neurosurgery (신경외과학교실) > 1. Journal Papers
Yonsei Authors
Kwon, Young Nam(권영남) ORCID logo https://orcid.org/0000-0002-3588-274X
Kim, Seung Woo(김승우) ORCID logo https://orcid.org/0000-0002-5621-0811
Kim, Eui Hyun(김의현) ORCID logo https://orcid.org/0000-0002-2523-7122
Moon, Ju Hyung(문주형)
Shin, Ha Young(신하영) ORCID logo https://orcid.org/0000-0002-4408-8265
Chang, Jong Hee(장종희) ORCID logo https://orcid.org/0000-0003-1509-9800
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/211513
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links