Pressure analysis during impression-making procedure with various tray designs using a digital occlusion analyzer: An in vitro study
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Sun, Minji | - |
| dc.contributor.author | Kim, Jaeyoung | - |
| dc.contributor.author | Choi, Seojune | - |
| dc.contributor.author | Moon, Hong Seok | - |
| dc.date.accessioned | 2026-01-29T06:26:27Z | - |
| dc.date.available | 2026-01-29T06:26:27Z | - |
| dc.date.created | 2025-08-28 | - |
| dc.date.issued | 2025-06 | - |
| dc.identifier.issn | 1059-941X | - |
| dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/210333 | - |
| dc.description.abstract | PurposeThe purpose of this study was to evaluate the pressures generated under various relief conditions during impression-making using the digital occlusal analyzer. Materials and MethodsA customized device and impression trays were designed to measure pressure during impression-making. The left half of the tray consistently had a 0.5 mm relief without vent holes as the control group, while the right half featured varying relief and vent hole designs, resulting in six different trays. Two impression materials (Materials A and B) were loaded onto each tray, and relative pressure was measured using the digital occlusal analyzer (T-Scan Novus, Tekscan, Inc.). The pressure-reduction ratio of each experimental side was calculated. Two-way analysis of variance (ANOVA) was used to evaluate the effect of relief conditions and impression materials on the pressure-reduction ratio, followed by post hoc multiple comparisons with Bonferroni adjustment (alpha = 0.05). ResultsThe pressure-reduction ratio was significantly influenced by both impression material and relief amount (p < 0.001), with a significant interaction between the two factors (p < 0.001). In Material A, pressure reduction was significantly greater at 3 mm compared to 1 and 2 mm, whereas in Material B, pressure reduction increased progressively with greater relief amount. Regarding vent hole design, both impression material and vent hole configuration significantly affected pressure reduction (p < 0.001), with no significant interaction (p = 0.767). Designs with smaller but more widely spread vent holes demonstrated significantly greater pressure reductions, with significant differences observed only between the single-hole design and the two- or five-hole designs. ConclusionsPressure reduction during impression making was influenced by both the viscosity of the material and the pressure-relief tray design. Forming vent holes yielded more consistent and effective results than adjusting the tray relief amount, highlighting the importance of a comprehensive approach that integrates both impression material selection and the application of various pressure-relief tray designs. | - |
| dc.language | English | - |
| dc.publisher | Wiley-Blackwell | - |
| dc.relation.isPartOf | JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | - |
| dc.relation.isPartOf | JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | - |
| dc.rights | CC BY-NC-ND 2.0 KR | - |
| dc.title | Pressure analysis during impression-making procedure with various tray designs using a digital occlusion analyzer: An in vitro study | - |
| dc.type | Article | - |
| dc.contributor.college | College of Dentistry (치과대학) | - |
| dc.contributor.department | Dept. of Prosthodontics (보철과학교실) | - |
| dc.contributor.googleauthor | Sun, Minji | - |
| dc.contributor.googleauthor | Kim, Jaeyoung | - |
| dc.contributor.googleauthor | Choi, Seojune | - |
| dc.contributor.googleauthor | Moon, Hong Seok | - |
| dc.identifier.doi | 10.1111/jopr.14087 | - |
| dc.relation.journalcode | J01719 | - |
| dc.identifier.eissn | 1532-849X | - |
| dc.identifier.pmid | 40550779 | - |
| dc.subject.keyword | complete denture | - |
| dc.subject.keyword | digital occlusal analyzer | - |
| dc.subject.keyword | impression making | - |
| dc.subject.keyword | pressure | - |
| dc.subject.keyword | relief | - |
| dc.subject.keyword | vent hole | - |
| dc.contributor.alternativeName | Kim, Jae-Young | - |
| dc.contributor.affiliatedAuthor | Kim, Jaeyoung | - |
| dc.contributor.affiliatedAuthor | Choi, Seojune | - |
| dc.contributor.affiliatedAuthor | Moon, Hong Seok | - |
| dc.identifier.scopusid | 2-s2.0-105008749865 | - |
| dc.identifier.wosid | 001513291300001 | - |
| dc.identifier.bibliographicCitation | JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2025-06 | - |
| dc.identifier.rimsid | 89205 | - |
| dc.type.rims | ART | - |
| dc.description.journalClass | 1 | - |
| dc.description.journalClass | 1 | - |
| dc.subject.keywordAuthor | complete denture | - |
| dc.subject.keywordAuthor | digital occlusal analyzer | - |
| dc.subject.keywordAuthor | impression making | - |
| dc.subject.keywordAuthor | pressure | - |
| dc.subject.keywordAuthor | relief | - |
| dc.subject.keywordAuthor | vent hole | - |
| dc.subject.keywordPlus | COMPLETE DENTURES | - |
| dc.subject.keywordPlus | RETENTION | - |
| dc.subject.keywordPlus | FORCE | - |
| dc.subject.keywordPlus | SPACE | - |
| dc.type.docType | Article; Early Access | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalWebOfScienceCategory | Dentistry, Oral Surgery & Medicine | - |
| dc.relation.journalResearchArea | Dentistry, Oral Surgery & Medicine | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.