Cited 0 times in 
Cited 0 times in 
Comparative analysis of novel damping capacity analysis devices for assessing implant stability in clinical practice
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Hong, Su-Bin | - |
| dc.contributor.author | Lee, Bo-Ah | - |
| dc.contributor.author | Lee, Woo-Ri | - |
| dc.contributor.author | Lee, Jung-Seok | - |
| dc.contributor.author | Kim, Young-Taek | - |
| dc.date.accessioned | 2026-01-23T05:37:22Z | - |
| dc.date.available | 2026-01-23T05:37:22Z | - |
| dc.date.created | 2026-01-16 | - |
| dc.date.issued | 2025-12 | - |
| dc.identifier.issn | 2093-2278 | - |
| dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/210247 | - |
| dc.description.abstract | Purpose: Implant stability testing is crucial for verifying osseointegration before prosthetic loading. Several methods have been developed to assess osseointegration. Among these, damping capacity analysis (DCA) devices offer a user-friendly and non-invasive approach. In this study, we evaluated the accuracy and reliability of newly available DCA devices in assessing dental implant stability. Methods: This study included 58 implants from 37 patients over a 1-month period. Three measurements per implant were obtained with healing abutments in place, following the manufacturers' guidelines, using the DCA-P (Periotest M, Medizintechnik Gulden), DCA-A (Anycheck, Neobiotech), and DCA-T (The Trust, Dentium) devices. Factors such as healing abutment height, time since placement, bone grafting, fixture diameter, and fixture length were evaluated. Accuracy was assessed using DCA-P as the reference, and reproducibility was statistically analyzed using 3 measurements per implant. Statistical analyses were performed with SPSS Statistics 23.0 (IBM Corp.). Results: All implants that passed the stability tests using DCA devices were restored with definitive prostheses and showed no signs of early failure. The DCA-A value demonstrated a very strong correlation with the DCA-P value (DCAV-P), whereas the DCA-T value exhibited only a moderate correlation with DCAV-P. DCA-P also showed the highest reliability, followed by DCA-A and then DCA-T. The reliability of DCA-A and DCA-T was not significantly affected by any of the assessed factors; in contrast, DCA-P's reliability was significantly influenced by arch location and specific quadrant position. Conclusions: With DCA-P as the reference, DCA-A demonstrated superior accuracy compared to DCA-T. Although DCA-P exhibited the highest reliability, its performance was significantly affected by the positional factors of the target implant. | - |
| dc.language | English | - |
| dc.publisher | Korean Academy of Periodontology | - |
| dc.relation.isPartOf | JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE | - |
| dc.relation.isPartOf | JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE | - |
| dc.title | Comparative analysis of novel damping capacity analysis devices for assessing implant stability in clinical practice | - |
| dc.type | Article | - |
| dc.contributor.googleauthor | Hong, Su-Bin | - |
| dc.contributor.googleauthor | Lee, Bo-Ah | - |
| dc.contributor.googleauthor | Lee, Woo-Ri | - |
| dc.contributor.googleauthor | Lee, Jung-Seok | - |
| dc.contributor.googleauthor | Kim, Young-Taek | - |
| dc.identifier.doi | 10.5051/jpis.2404680234 | - |
| dc.relation.journalcode | J01695 | - |
| dc.identifier.eissn | 2093-2286 | - |
| dc.identifier.pmid | 40501076 | - |
| dc.subject.keyword | Dental implants | - |
| dc.subject.keyword | Diagnostic techniques and procedures | - |
| dc.subject.keyword | Osseointegration | - |
| dc.contributor.affiliatedAuthor | Lee, Jung-Seok | - |
| dc.identifier.scopusid | 2-s2.0-105026873921 | - |
| dc.identifier.wosid | 001654367100005 | - |
| dc.citation.volume | 55 | - |
| dc.citation.number | 6 | - |
| dc.citation.startPage | 462 | - |
| dc.citation.endPage | 472 | - |
| dc.identifier.bibliographicCitation | JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, Vol.55(6) : 462-472, 2025-12 | - |
| dc.identifier.rimsid | 91075 | - |
| dc.type.rims | ART | - |
| dc.description.journalClass | 1 | - |
| dc.description.journalClass | 1 | - |
| dc.subject.keywordAuthor | Dental implants | - |
| dc.subject.keywordAuthor | Diagnostic techniques and procedures | - |
| dc.subject.keywordAuthor | Osseointegration | - |
| dc.subject.keywordPlus | RESONANCE FREQUENCY-ANALYSIS | - |
| dc.subject.keywordPlus | IN-VITRO | - |
| dc.subject.keywordPlus | RELIABILITY | - |
| dc.subject.keywordPlus | PERIOTEST | - |
| dc.subject.keywordPlus | DIAGNOSIS | - |
| dc.subject.keywordPlus | VALIDITY | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART003288051 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalWebOfScienceCategory | Dentistry, Oral Surgery & Medicine | - |
| dc.relation.journalResearchArea | Dentistry, Oral Surgery & Medicine | - |