5 21

Cited 0 times in

Cited 0 times in

Comparative analysis of novel damping capacity analysis devices for assessing implant stability in clinical practice

DC Field Value Language
dc.contributor.authorHong, Su-Bin-
dc.contributor.authorLee, Bo-Ah-
dc.contributor.authorLee, Woo-Ri-
dc.contributor.authorLee, Jung-Seok-
dc.contributor.authorKim, Young-Taek-
dc.date.accessioned2026-01-23T05:37:22Z-
dc.date.available2026-01-23T05:37:22Z-
dc.date.created2026-01-16-
dc.date.issued2025-12-
dc.identifier.issn2093-2278-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/210247-
dc.description.abstractPurpose: Implant stability testing is crucial for verifying osseointegration before prosthetic loading. Several methods have been developed to assess osseointegration. Among these, damping capacity analysis (DCA) devices offer a user-friendly and non-invasive approach. In this study, we evaluated the accuracy and reliability of newly available DCA devices in assessing dental implant stability. Methods: This study included 58 implants from 37 patients over a 1-month period. Three measurements per implant were obtained with healing abutments in place, following the manufacturers' guidelines, using the DCA-P (Periotest M, Medizintechnik Gulden), DCA-A (Anycheck, Neobiotech), and DCA-T (The Trust, Dentium) devices. Factors such as healing abutment height, time since placement, bone grafting, fixture diameter, and fixture length were evaluated. Accuracy was assessed using DCA-P as the reference, and reproducibility was statistically analyzed using 3 measurements per implant. Statistical analyses were performed with SPSS Statistics 23.0 (IBM Corp.). Results: All implants that passed the stability tests using DCA devices were restored with definitive prostheses and showed no signs of early failure. The DCA-A value demonstrated a very strong correlation with the DCA-P value (DCAV-P), whereas the DCA-T value exhibited only a moderate correlation with DCAV-P. DCA-P also showed the highest reliability, followed by DCA-A and then DCA-T. The reliability of DCA-A and DCA-T was not significantly affected by any of the assessed factors; in contrast, DCA-P's reliability was significantly influenced by arch location and specific quadrant position. Conclusions: With DCA-P as the reference, DCA-A demonstrated superior accuracy compared to DCA-T. Although DCA-P exhibited the highest reliability, its performance was significantly affected by the positional factors of the target implant.-
dc.languageEnglish-
dc.publisherKorean Academy of Periodontology-
dc.relation.isPartOfJOURNAL OF PERIODONTAL AND IMPLANT SCIENCE-
dc.relation.isPartOfJOURNAL OF PERIODONTAL AND IMPLANT SCIENCE-
dc.titleComparative analysis of novel damping capacity analysis devices for assessing implant stability in clinical practice-
dc.typeArticle-
dc.contributor.googleauthorHong, Su-Bin-
dc.contributor.googleauthorLee, Bo-Ah-
dc.contributor.googleauthorLee, Woo-Ri-
dc.contributor.googleauthorLee, Jung-Seok-
dc.contributor.googleauthorKim, Young-Taek-
dc.identifier.doi10.5051/jpis.2404680234-
dc.relation.journalcodeJ01695-
dc.identifier.eissn2093-2286-
dc.identifier.pmid40501076-
dc.subject.keywordDental implants-
dc.subject.keywordDiagnostic techniques and procedures-
dc.subject.keywordOsseointegration-
dc.contributor.affiliatedAuthorLee, Jung-Seok-
dc.identifier.scopusid2-s2.0-105026873921-
dc.identifier.wosid001654367100005-
dc.citation.volume55-
dc.citation.number6-
dc.citation.startPage462-
dc.citation.endPage472-
dc.identifier.bibliographicCitationJOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, Vol.55(6) : 462-472, 2025-12-
dc.identifier.rimsid91075-
dc.type.rimsART-
dc.description.journalClass1-
dc.description.journalClass1-
dc.subject.keywordAuthorDental implants-
dc.subject.keywordAuthorDiagnostic techniques and procedures-
dc.subject.keywordAuthorOsseointegration-
dc.subject.keywordPlusRESONANCE FREQUENCY-ANALYSIS-
dc.subject.keywordPlusIN-VITRO-
dc.subject.keywordPlusRELIABILITY-
dc.subject.keywordPlusPERIOTEST-
dc.subject.keywordPlusDIAGNOSIS-
dc.subject.keywordPlusVALIDITY-
dc.type.docTypeArticle-
dc.identifier.kciidART003288051-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalWebOfScienceCategoryDentistry, Oral Surgery & Medicine-
dc.relation.journalResearchAreaDentistry, Oral Surgery & Medicine-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Periodontics (치주과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.