1 3

Cited 0 times in

Cited 0 times in

Validating clinical feasibility of MRCAT and deep learning-based synthetic CT images for cervical cancer patient

Authors
 Yoo, Dohyeon  ;  Kim, Hojin  ;  Park, Sangjoon  ;  Choi, Hyeok  ;  Kim, Se Young  ;  Kim, Jin Sung  ;  Kim, Yong Bae 
Citation
 JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, Vol.26(11), 2025-11 
Article Number
 e70332 
Journal Title
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS
ISSN
 1526-9914 
Issue Date
2025-11
MeSH
Algorithms ; Deep Learning* ; Feasibility Studies ; Female ; Humans ; Image Processing, Computer-Assisted* / methods ; Magnetic Resonance Imaging* / methods ; Organs at Risk / radiation effects ; Radiotherapy Dosage ; Radiotherapy Planning, Computer-Assisted* / methods ; Radiotherapy, Intensity-Modulated / methods ; Tomography, X-Ray Computed* / methods ; Uterine Cervical Neoplasms* / diagnostic imaging ; Uterine Cervical Neoplasms* / radiotherapy
Keywords
cervical cancer ; deep-learning ; MR images ; MRCAT ; synthetic CT image
Abstract
Background Various methods have been developed to generate synthetic computed tomography (CT) images from magnetic resonance (MR) images, including segmentation-based approach with MR calculating attenuation (MRCAT) and deep learning (DL)-based approach.Purpose In this study, we aimed to validate the conventional radiotherapy (RT) planning process with MRCAT and DL-based synthetic CT images for five patients with cervical cancer.Methods DL-based synthetic CT images of the five patients were inferred using a network trained with 40 pairs of CT and deformed, normalized T2-weighted MR scans; MRCAT images were obtained from mDixon sequences for the tested cases only. On the synthetic CT images, the contouring process for organs-at-risk (OARs) was automatically performed with minor adjustments, while two experienced radiation oncologists defined target volumes. Simultaneous integrated boost plans (2.2/2.0/1.8 Gy with 25 fractions) were produced from a commercial treatment planning system (TPS) TomoTherapy.Results The plans with two synthetic CT images were compared with those based on genuine CT images for the five test cases. High geometric similarity was confirmed for the planning target volume (PTV), with average dice similarity coefficient (DSC) of 0.844 for the DL-based and 0.829 for the MRCAT images. The mean percentage difference in gross tumor volume (GTV) was 20.71 +/-$ \pm $ 34.28% for DL-based synthetic CT and 30.31 +/-$ \pm $ 46.20% for MRCAT images. By contrast, PTV, encompassing GTV, exhibited minimal changes with an average increase of 0.37 +/-$ \pm $ 3.10% and 1.66 +/-$ \pm $ 7.62%, respectively. MRCAT images and DL-based synthetic CT revealed significant differences, relative to true CT images, in the entire volume (p = 0.03) of the bladder and in V20Gy and V30Gy of the resultant plans for the bladder (p = 0.029 and 0.063), all plans generated on the synthetic CTs were clinically acceptable and met institutional for target coverage.Conclusion MRCAT and DL-based synthetic CT images demonstrated clinical applicability, achieving plan quality similar to that of plans based on genuine planning CT images.
Files in This Item:
90299.pdf Download
DOI
10.1002/acm2.70332
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiation Oncology (방사선종양학교실) > 1. Journal Papers
Yonsei Authors
Kim, Yong Bae(김용배) ORCID logo https://orcid.org/0000-0001-7573-6862
Kim, Jinsung(김진성) ORCID logo https://orcid.org/0000-0003-1415-6471
Kim, Hojin(김호진) ORCID logo https://orcid.org/0000-0002-4652-8682
Park, Sang Joon(박상준)
Yoo, Dohyeon(유도현)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/209539
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links