0 0

Cited 0 times in

Cited 0 times in

Effect of X-Ray Tube Angulations and Digital Sensor Alignments on Profile Angle Distortion of CAD-CAM Abutments: A Pilot Radiographic Study

Authors
 Choi, Chang-Hun  ;  Back, Seungwon  ;  Kim, Sunjai 
Citation
 BIOENGINEERING-BASEL, v.12, no.7 
Journal Title
 BIOENGINEERING-BASEL 
ISSN
 2306-5354 
Issue Date
2025-07
Keywords
periapical radiograph ; accuracy ; profile angle ; X-ray tube angulation ; digital sensor angulation
Abstract
Purpose: This pilot study aimed to evaluate how deviations in X-ray tube head angulation and digital sensor alignment affect the radiographic measurement of the profile angle in CAD-CAM abutments. Materials and Methods: A mandibular model was used with five implant positions (central, buccal, and lingual offsets). Custom CAD-CAM abutments were designed with identical bucco-lingual direction contours and varying mesio-distal asymmetry for the corresponding implant positions. Periapical radiographs were acquired under controlled conditions by systematically varying vertical tube angulation, horizontal tube angulation, and horizontal sensor rotation from 0 degrees to 20 degrees in 5 degrees increments for each parameter. Profile angles, interthread distances, and proximal overlaps were measured and compared with baseline STL data. Results: Profile angle measurements were significantly affected by both X-ray tube and sensor deviations. Horizontal tube angulation produced the greatest profile angle distortion, particularly in buccally positioned implants. Vertical x-ray tube angulations beyond 15 degrees led to progressive underestimation of profile angles, while horizontal tube head rotation introduced asymmetric mesial-distal variation. Sensor rotation also caused marked interthread elongation, in some cases exceeding 100%, despite vertical projection being maintained. Profile angle deviations greater than 5 degrees occurred in multiple conditions. Conclusions: X-ray tube angulation and sensor alignment influence the reliability of profile angle measurements. Radiographs with > 10% interthread elongation or crown overlap may be inaccurate and warrant re-acquisition. Special attention is needed when imaging buccally positioned implants.
Files in This Item:
89534.pdf Download
Article Number
 772 
DOI
10.3390/bioengineering12070772
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Prosthodontics (보철과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Sun Jai(김선재) ORCID logo https://orcid.org/0000-0002-0828-8008
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/207970
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links