8 35

Cited 0 times in

Cited 0 times in

Revealing the Three-Dimensional Complexity of Facial Anatomy Through Micro-Computed Tomography

DC Field Value Language
dc.contributor.authorYi, Kyu-Ho-
dc.contributor.authorWan, Jovian-
dc.contributor.authorSong, Jong Keun-
dc.contributor.authorSwift, Arthur-
dc.contributor.authorAscher, Benjamin-
dc.date.accessioned2025-10-24T07:59:10Z-
dc.date.available2025-10-24T07:59:10Z-
dc.date.created2025-09-22-
dc.date.issued2025-08-
dc.identifier.issn1473-2130-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/207929-
dc.description.abstractBackground: Micro-computed tomography (micro-CT) offers exceptional three-dimensional resolution for studying facial anatomy, capturing intricate structural relationships with isotropic resolutions as fine as 4-10 mu m. However, its use is limited to ex vivo specimens, precluding real-time or functional evaluation. Objective: To highlight the complementary value of high-frequency ultrasound in facial anatomical assessment and procedural guidance, particularly in the clinical context. Methods: We discuss the limitations of micro-CT for dynamic applications and explore the clinical advantages of ultrasound, including Doppler capabilities and real-time observation of soft tissue structures. Results: High-frequency ultrasound (30-70 mu m resolution) enables in vivo, dynamic imaging of vascular flow, muscle activity, and filler placement. It is non-invasive, repeatable, and applicable at the point of care. Finger-mounted devices, such as those used in Safe Injection By Ultrasound (SIBUS) protocols, provide sufficient resolution for guiding aesthetic procedures involving superficial facial anatomy. Doppler integration further enhances procedural safety. Conclusion: While micro-CT remains ideal for high-resolution anatomical research and educational modeling, ultrasound uniquely enables functional, real-time assessment essential for safe clinical practice. Together, these modalities serve complementary roles in advancing both anatomical understanding and patient care in aesthetic medicine.-
dc.languageEnglish-
dc.publisherBlackwell Science-
dc.relation.isPartOfJOURNAL OF COSMETIC DERMATOLOGY-
dc.relation.isPartOfJOURNAL OF COSMETIC DERMATOLOGY-
dc.subject.MESHCosmetic Techniques*-
dc.subject.MESHDermal Fillers / administration & dosage-
dc.subject.MESHFace* / anatomy & histology-
dc.subject.MESHFace* / blood supply-
dc.subject.MESHFace* / diagnostic imaging-
dc.subject.MESHHumans-
dc.subject.MESHImaging, Three-Dimensional* / methods-
dc.subject.MESHUltrasonography, Doppler / methods-
dc.subject.MESHX-Ray Microtomography* / methods-
dc.titleRevealing the Three-Dimensional Complexity of Facial Anatomy Through Micro-Computed Tomography-
dc.typeArticle-
dc.contributor.googleauthorYi, Kyu-Ho-
dc.contributor.googleauthorWan, Jovian-
dc.contributor.googleauthorSong, Jong Keun-
dc.contributor.googleauthorSwift, Arthur-
dc.contributor.googleauthorAscher, Benjamin-
dc.identifier.doi10.1111/jocd.70379-
dc.relation.journalcodeJ03077-
dc.identifier.eissn1473-2165-
dc.identifier.pmid40776607-
dc.subject.keywordaesthetic injection safety-
dc.subject.keywordfacial anatomy-
dc.subject.keywordmicro-CT-
dc.subject.keywordSIBUS-
dc.subject.keywordultrasound-
dc.contributor.affiliatedAuthorYi, Kyu-Ho-
dc.identifier.scopusid2-s2.0-105012764116-
dc.identifier.wosid001554433700008-
dc.citation.volume24-
dc.citation.number8-
dc.identifier.bibliographicCitationJOURNAL OF COSMETIC DERMATOLOGY, Vol.24(8), 2025-08-
dc.identifier.rimsid89453-
dc.type.rimsART-
dc.description.journalClass1-
dc.description.journalClass1-
dc.subject.keywordAuthoraesthetic injection safety-
dc.subject.keywordAuthorfacial anatomy-
dc.subject.keywordAuthormicro-CT-
dc.subject.keywordAuthorSIBUS-
dc.subject.keywordAuthorultrasound-
dc.type.docTypeEditorial Material-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalWebOfScienceCategoryDermatology-
dc.relation.journalResearchAreaDermatology-
dc.identifier.articlenoe70379-
Appears in Collections:
7. Others (기타) > Others (기타) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.