Cited 0 times in

교정적 치아 이동 후 재발에 대한 백서 모델 확립을 위한 예비 연구: Elastomeric Power Chain vs. Ni-Ti Coil Spring

Other Titles
 A Pilot Study for Establishing Rat Models of Relapse Following Orthodontic Tooth Movement: Elastomeric Power Chain vs. Ni-Ti Coil Spring 
Authors
 안현나  ;  허지선  ;  정서연 
Citation
 Korean Academy of Advanced General Dentistry (대한통합치과학회), Vol.12(2) : 33-42, 2023-05 
Journal Title
Korean Academy of Advanced General Dentistry(대한통합치과학회)
Issue Date
2023-05
Keywords
Orthodontic relapse ; Osteoclastogenesis ; Immunohistochemistry ; Animal models
Abstract
This study aims to establish experimental animal models for orthodontic tooth movement and orthodontic relapse using an elastomeric power chain and nickel-titanium (Ni-Ti) coil spring, which are most commonly used in clinical practice. The amount of orthodontic tooth movement and relapse in rats according to the two materials was measured, and the histological differences and the expression of molecules involved in bone turnover were compared. Two female Sprague-Dawley rats were induced orthodontic tooth movement for 14 days by applying orthodontic materials to right and left maxillary first molars. 7 days after the device removes, the relapse rate and the effect on periodontal tissue were evaluated through tooth movement, micro-CT taking, hematoxylin and eosin (H&E) and tartrate-resistant acid phosphatase (TRAP) staining, and immunohistochemistry (IHC) analysis. The result of measuring the relapse rate on the 7th day after applying orthodontic force for 14 days was measured as 60.7% and 77.8% in the E.B and C.S groups, respectively. As a result of analyzing the root furcation area of the maxillary first molar, the E.B group tend to show a smaller BV/TV value than the C.S group, but the values of other parameters were similar. The number of TRAP-positive osteoclasts was higher on the compression side than on the tension side, and there was no significant difference between the two groups. The OPG, RANKL, and sclerostinpositive cells measured on the compression side also showed no significant difference. In the experimental model using the elastomeric power chain, no evidence was found that it was inaccurate or more inflammatory than the Ni-Ti coil spring model, and when considering the hygiene and convenience of the subject, it was suitable for use in the model.
Files in This Item:
T992025319.pdf Download
DOI
10.23034/jkaagd.2023.12.2.33
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Dental Education (치의학교육학교실) > 1. Journal Papers
Yonsei Authors
Jung, Seoyeon(정서연)
Huh, Jisun(허지선) ORCID logo https://orcid.org/0000-0001-5514-187X
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/205269
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links